Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机GC with an Agilent CP-Molsieve 5Å column module and Agilent 490 Micro GC separates neon, nitrogen, hydrogen and argon in a xenon test mix in 66 seconds.
- Publication Part Number: A0871
- Created: 31 Oct 2011
- 441 KB
Publication Part Number | A00871 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC analyzes helium and oxygen impurities in nitrogen in 25 seconds.
- Publication Part Number: A0858
- Created: 31 Oct 2011
- 418 KB
Publication Part Number | A00858 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separate oxygen, nitrogen, methane, carbon dioxide, and hydrogen in 30 seconds.
- Publication Part Number: A0855
- Created: 31 Oct 2011
- 577 KB
Publication Part Number | A00855 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates oxygen, nitrogen, methane, and xenon in 75 seconds.
- Publication Part Number: A0859
- Created: 31 Oct 2011
- 413 KB
Publication Part Number | A00859 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01237
- Created: 31 Oct 2011
- 343 KB
Publication Part Number | A01237 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates oxygen, nitrogen, methane and carbon monoxide in coke gas in 55 seconds.
- Publication Part Number: A0869
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00869 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates oxygen and nitrogen in 27 seconds.
- Publication Part Number: A0856
- Created: 31 Oct 2011
- 307 KB
Publication Part Number | A00856 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates spiked neon and hydrogen in air in 39 seconds.
- Publication Part Number: A0866
- Created: 31 Oct 2011
- 421 KB
Publication Part Number | A00866 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Agilent 490 Micro GC with an Agilent J&W CP-Molsieve 5Å analyzes air near a garbage dump for neon, hydrogen, oxygen, nitrogen, methane and carbon monoxide in 240 s.
- Publication Part Number: A01619
- Created: 31 Oct 2011
- 417 KB
Publication Part Number | A01619 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01238
- Created: 31 Oct 2011
- 357 KB
Publication Part Number | A01238 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates helium, oxygen, nitrogen, methane, hydrogen, and carbon monoxide in 70 s.
- Publication Part Number: A0870
- Created: 31 Oct 2011
- 352 KB
Publication Part Number | A00870 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates helium, hydrogen and nitrogen in 25 seconds.
- Publication Part Number: A0857
- Created: 31 Oct 2011
- 408 KB
Publication Part Number | A00857 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01242
- Created: 31 Oct 2011
- 382 KB
Publication Part Number | A01242 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|