必威体育登录手机Agilent J&W HP-PLOT Q PT and HP-PLOT U PT GC columns were evaluated for coal-to-chemical process gas analysis by GC/TCD and GC/MS detection.
- Publication Part Number: 5991-2205EN
- Created: 03 Apr 2013
- 262 KB
Publication Part Number | 5991-2205EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机This note describes the use of an Agilent 490-PRO Micro GC for the analysis of liquefied propane and butane (LPG) streams for plant quality control and plant processing.
- Publication Part Number: 5991-1972EN
- Created: 11 Mar 2013
- 449 KB
Publication Part Number | 5991-1972EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates eight C1 to C4 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0606
- Created: 31 Oct 2011
- 575 KB
Publication Part Number | A00606 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates components in natural gas in 55 seconds.
- Publication Part Number: A0878
- Created: 31 Oct 2011
- 423 KB
Publication Part Number | A00878 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q column separates 11 C1 to C6 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0607
- Created: 31 Oct 2011
- 639 KB
Publication Part Number | A00607 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-AL2O3/KCl column module and Agilent 490 Micro GC separates 14 C1 to C4 hydrocarbons in 200 seconds.
- Publication Part Number: A0906
- Created: 31 Oct 2011
- 675 KB
Publication Part Number | A00906 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|