Refine Results
- 必威体育赛事投注
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Fast GC analysis of THT and TBM in natural gas in under two minutes using an Agilent J&W Lowox column.
- Publication Part Number: A02248
- Created: 31 Oct 2011
- 820 KB
Publication Part Number | A02248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 C1 to C8 light hydrocarbons in natural gas in 20 minutes.
- Publication Part Number: A00226
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A00226 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GCwith an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates methane, propane, ethane, and carbon dioxide in natural gas in 70 seconds.
- Publication Part Number: A0890
- Created: 31 Oct 2011
- 364 KB
Publication Part Number | A00890 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机GC separation of propanal from propylene oxide is achieved in eight minutes using an Agilent J&W PoraBOND U column.
- Publication Part Number: A02049
- Created: 31 Oct 2011
- 389 KB
Publication Part Number | A02049 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 23 C1 to C7 hydrocarbons in natural gas in 50 minutes.
- Publication Part Number: A0271
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00271 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC using an Agilent J&W CP-Sil 5 CB separates three sulfur gases, hydrogen sulfide, carbonyl sulfide, and methyl mercaptan, from natural gas according to ASTM D5504.
- Publication Part Number: A01643
- Created: 31 Oct 2011
- 531 KB
Publication Part Number | A01643 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 16 C1 to C7 hydrocarbons in natural gas in 25 minutes.
- Publication Part Number: A0117
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A00117 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Fast gas chromatography of sulfur compounds in natural gas takes 100 seconds using the MES module PLOT column in the Agilent 490 Micro GC.
- Publication Part Number: A01708
- Created: 31 Oct 2011
- 513 KB
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates C3 to C7 hydrocarbons in a sample of naphtha in 60 minutes.
- Publication Part Number: A0165
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A00165 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Application note for the analysis of Low-Level Sulfur Compounds in Natural Gas and Propylene Using a Pulsed Flame Photometric Detector
- Publication Part Number: 5990-9215EN
- Created: 20 Oct 2011
- 1 MB
Publication Part Number | 5990-9215EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机This application note shows the possibilities and limitations in fast analysis of saturated and unsaturated C1 to C3 hydrocarbons using an Agilent 490 Micro GC.
- Publication Part Number: 5990-9165EN
- Created: 04 Oct 2011
- 320 KB
Publication Part Number | 5990-9165EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of Methyl Ethyl Sulfide (MES) in Natural Gas using the Agilent 490 Micro GC
- Publication Part Number: 5990-8750EN
- Created: 26 Aug 2011
- 133 KB
Publication Part Number | 5990-8750EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Applicaiton note for the analysis of Tetrahydrothiophene (THT) in Natural Gas using the Agilent 490 Micro GC
- Publication Part Number: 5990-8528EN
- Created: 29 June 2011
- 537 KB
Publication Part Number | 5990-8528EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Application note for the analysis of tert-Butyl Mercaptan inNatural Gas on a CP-Sil 13 CB Using the 490 GC
- Publication Part Number: 5990-8250EN
- Created: 27 May 2011
- 360 KB
Publication Part Number | 5990-8250EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
A solution to test for permanent gases and light hydrocarbons.
- Publication Part Number: 5990-4667EN
- Created: 13 Oct 2009
- 358 KB
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Application note for high-pressure injection device for the Agilent 7890A and 6890 Series Gas Chromatographs Accessory
- Publication Part Number: 5989-8037EN
- Created: 25 Feb 2008
- 174 KB
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Application note for the analysis of permanent gases and methane with the Agilent 6820 Gas Chromatograph
- Publication Part Number: 5988-9260EN
- Created: 07 May 2003
- 144 KB
Application note for Dual-Channel Gas Chromatographic System for the Determination of Low-Level Sulfur in Hydrocarbon Gases
- Publication Part Number: 5988-8904EN
- Created: 17 Mar 2003
- 202 KB
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机本實驗選擇了新型硫化物分析專用型色譜柱 — Agilent DB-Sulfur SCD,利用同一支色譜柱,既能檢測汽油中揮發性硫化物的分布情況,又可以使柴油中重質烴類和含硫化合物在 40 m 薄膜柱上獲得適當的保留和良好的分離。
- Publication Part Number: 5991-7040CHCN
- Created: 14 July 2016
- 5 MB
解決氣相柱QC 測試中所關注的問題
- Publication Part Number: 5990-9961CHCN
- Created: 05 Mar 2012
- 647 KB
Publication Part Number | 5990-9961EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|