Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Compounds
-
Compounds
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Column choice in SEC depends on column resolving range, identified by calibration with standards appropriate to analyte type, molecular weight range, and size in solution.
- Publication Part Number: 5991-2463EN
- Created: 14 May 2013
- 117 KB
Publication Part Number | 5991-2463EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Methods are given for the use of Agilent Bio-SEC columns, with LS, UV and RI detection, for quantification or quality control of protein aggregates
- Publication Part Number: 5991-1400EN
- Created: 07 Jan 2013
- 284 KB
Publication Part Number | 5991-1400EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
A mixture of standard proteins was used to determine the resolution characteristics of the columns...
- Publication Part Number: 5990-8895EN
- Created: 13 Sep 2011
- 703 KB
Publication Part Number | 5990-8895EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
The aggregation of protein therapeutics has become a major concern for the
- Publication Part Number: 5990-8613EN
- Created: 02 Aug 2011
- 602 KB
Publication Part Number | 5990-8613EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for the characterization of monoclonal antibodies on the Agilent 1260 Infinity Bio-inert Quaternary LC by SEC using the Agilent BioSEC columns
- Publication Part Number: 5990-6414EN
- Created: 01 Feb 2011
- 996 KB
Publication Part Number | 5990-6414EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|