This study provides examples of the use of a combination upright and inverted automated image acquisition system for performing WSI employing ROIs where applicable.
- Publication Part Number: 5994-3404EN
- Created: 04 May 2022
- 1 MB
必威体育登录手机This application note describes the capability of the Agilent BioTek BioSpa 8 automated incubator to perform automated cytotoxicity testing.
- Publication Part Number: 5994-3375EN
- Created: 04 May 2022
- 1 MB
This study describes a magnetic 3D bioprinting cell culture platform, where cells are first incubated with a biocompatible magnetic nanoparticle assembly.
- Publication Part Number: 5994-3376EN
- Created: 20 Apr 2022
- 3 MB
This application notes describes the use of automated image capture to visualize cell retention and monolayer integrity across the microplate well surface.
- Publication Part Number: 5994-3363EN
- Created: 08 Apr 2022
- 2 MB
This study presents two bioprinting procedures using different magnet geometries that enable in vitro 3D wound healing and metastatic cell migration experiments.
- Publication Part Number: 5994-3383EN
- Created: 08 Apr 2022
- 3 MB
This study outlines a procedure for the creation of 3D spheroidal tumoroid structures, automated kinetic image-based monitoring, and cell analysis of tumor invasion.
- Publication Part Number: 5994-3393EN
- Created: 08 Apr 2022
- 4 MB
必威体育登录手机This application note describes the automation of the non-alcoholic fatty liver disease model assay workflow using Agilent BioTek instrumentation.
- Publication Part Number: 5994-3380EN
- Created: 08 Apr 2022
- 1 MB
This application note demonstrates the performance of the AlphaLISA SureFire Ultra assays for detection of phosphorylated proteins.
- Publication Part Number: 5994-3361EN
- Created: 08 Apr 2022
- 357 KB
This application note demonstrates the automation of a HTS-compatible homogenous proximity assay for the detection of residual Protein A in biological therapeutics.
- Publication Part Number: 5994-3350EN
- Created: 31 Mar 2022
- 279 KB
This application brief demonstrates the ability of the Synergy LX multimode reader to measure fluorescence and determine GFP transfection efficiency.
- Publication Part Number: 5994-2763EN
- Created: 31 Mar 2022
- 512 KB
This application note presents data using PrimeSurface ULA plates to develop spheroid assays for brightfield and fluorescence imaging.
- Publication Part Number: 5994-3389EN
- Created: 31 Mar 2022
- 2 MB
This application note presents an automated method for conducting and analyzing the colony formation assay in both a 6-well and 96-well microplate.
- Publication Part Number: 5994-3403EN
- Created: 31 Mar 2022
- 1 MB
This study describes the use of automated object-based spot counting to quantitatively assess the effects of starvation and rapamycin on cellular autophagy.
- Publication Part Number: 5994-3378EN
- Created: 31 Mar 2022
- 1 MB
This application brief demonstrates the use of the Auto ROI feature of Gen5 to identify mitotic cells for further characterization using confocal microscopy.
- Publication Part Number: 5994-3504EN
- Created: 17 Mar 2022
- 657 KB
Efficiently screen for inhibitors of MT1-MMP activity and 3D glioma tumoroid invasion using a fluorescent substrate-based MMP activity assay and hit pick reading/imaging procedure.
- Publication Part Number: 5994-4457EN
- Created: 14 Mar 2022
- 3 MB
必威体育登录手机In this application note, chloroquine was used to demonstrate that LUCS assay can be implemented in a "plug-and-play" mode using the Agilent BioTek Cytation 5.
- Publication Part Number: 5994-4598EN
- Created: 28 Feb 2022
- 679 KB
必威体育登录手机In this application note, the Agilent BioTek Cytation 5 cell imaging multimode reader was used for quantitative assessment of antioxidant activities in living cells.
- Publication Part Number: 5994-4600EN
- Created: 28 Feb 2022
- 1 MB
This application note demonstrates a method to automate detection and analysis of high throughput comet-based genotoxicity data using Cytation 5.
- Publication Part Number: 5994-2595EN
- Created: 14 Dec 2021
- 1 MB
必威体育登录手机This application brief shows how the Agilent BioTek Cytation C10 confocal imaging reader improves the resolution of mouse retinal vasculature, compared to widefield microscopy.
- Publication Part Number: 5994-4059EN
- Created: 01 Dec 2021
- 2 MB
必威体育登录手机This application note describes whole-organism imaging of spinal motor neurons and musculature using the Agilent BioTek Cytation C10 confocal imaging reader.
- Publication Part Number: 5994-4061EN
- Created: 01 Dec 2021