必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates components in Aroclor 1016, 1221, 1232, and 1242 according to EPA 8080 in 50 minutes.
- Publication Part Number: A0797
- Created: 31 Oct 2011
- 804 KB
Publication Part Number | A00797 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates nine nitroaromatics and cyclic ketones according to EPA 8090 in 33 minutes.
- Publication Part Number: A0800
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A00800 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 19 organochlorine pesticides according to EPA 8080 in 50 minutes.
- Publication Part Number: A0796
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00796 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 12 organochlorine components in toxaphene according to EPA 8080 in 55 minutes.
- Publication Part Number: A0799
- Created: 31 Oct 2011
- 602 KB
Publication Part Number | A00799 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates components in Aroclor 1248, 1254, and 1260 according to EPA 8080 in 60 minutes.
- Publication Part Number: A0798
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00798 | |||
---|---|---|---|---|