必威体育登录手机Gas chromatography using an Agilent J&W CP-FFAP column separates eight phenols in six minutes.
- Publication Part Number: A0361
- Created: 31 Oct 2011
- 648 KB
Publication Part Number | A00361 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Cresol column separates eight cresols in a sample of cresol soap in 20 minutes.
- Publication Part Number: A0965
- Created: 31 Oct 2011
- 535 KB
Publication Part Number | A00965 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Chirasil-DEX CB column separates 14 phenol and cresol isomers in ten minutes.
- Publication Part Number: A01449
- Created: 31 Oct 2011
- 591 KB
Publication Part Number | A01449 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC separation of 12 phenols using an Agilent J&W CP-Sil 19 CB column with FID is achieved in 15 minutes.
- Publication Part Number: A01953
- Created: 31 Oct 2011
- 736 KB
Publication Part Number | A01953 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates eight phenols and cresols in eight minutes.
- Publication Part Number: A0354
- Created: 31 Oct 2011
- 614 KB
Publication Part Number | A00354 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 43 CB column separates 14 phenols in about 50 minutes.
- Publication Part Number: A00088
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00088 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|