必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 47 solvents and other volatiles according to EPA 8240 in 42 minutes.
- Publication Part Number: A0804
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A00804 | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 71 halogenated hydrocarbons in water according to EPA 524.5, in 60 minutes.
- Publication Part Number: A1017
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates nine solvents in 11 minutes.
- Publication Part Number: A0905
- Created: 31 Oct 2011
- 696 KB
Publication Part Number | A00905 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column separates 16 solvents in 35 minutes.
- Publication Part Number: A0109
- Created: 31 Oct 2011
- 621 KB
Publication Part Number | A00109 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 12 chlorofluorocarbons in 30 minutes.
- Publication Part Number: A0919
- Created: 31 Oct 2011
- 720 KB
Publication Part Number | A00919 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates eight halogenated degradation products of tetrachloroethylene in surface water in 10 minutes.
- Publication Part Number: A01426
- Created: 31 Oct 2011
- 483 KB
Publication Part Number | A01426 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 19 solvents in 17 minutes.
- Publication Part Number: A0719
- Created: 31 Oct 2011
- 680 KB
Publication Part Number | A00719 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using Agilent J&W PoraPLOT Q and PoraPLOT Q-HT columns separate 22 C1to C8 hydrocarbons and C1 to C2 halogenated hydrocarbons in 30 minutes.
- Publication Part Number: A01268
- Created: 31 Oct 2011
- 711 KB
Publication Part Number | A01268 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Analysis of low levels of bromochloromethane in chloroform is done by GC/MS with Agilent J&W PoraBOND Q columns in 12 minutes.
- Publication Part Number: A01919
- Created: 01 Oct 2011
- 631 KB
Publication Part Number | A01919 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机A gas chromatograph with a built in cryogenic concentrator and Agilent J&W CP-Select 624 CB column separates ten volatile organic compounds in a sample of ambient air.
- Publication Part Number: A01862
- Created: 01 Oct 2011
- 2 MB
Publication Part Number | A01862 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机An Agilent J&W CP-Select 624 column and gas chromatography separates 38 volatile organic compounds in water using PID and ELCD detectors.
- Publication Part Number: A01847
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01847 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机To achieve method detection limits for volatile organic compounds (sub ppb) in air, sample concentration before analysis on Agilent J&W CP-Select 624 is needed.
- Publication Part Number: A01853
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01853 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W VF-624ms column separates 27 residual solvents in 40 minutes.
- Publication Part Number: A02400
- Created: 11 May 2010
- 807 KB
Publication Part Number | A02400 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机For USP-467 with Agilent J&W VF-624ms, replacing a 30 m x 0.32 mm column for one of 15 m x 0.15 mm reduces analysis time by more than half.because the efficiency is higher.
- Publication Part Number: A02430
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02430 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|