必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column separates six volatile aromatic hydrocarbons at low concentrations in water in 13 minutes.
- Publication Part Number: A0219
- Created: 31 Oct 2011
- 469 KB
Publication Part Number | A00219 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates several aromatics, and butanol, in 20 minutes.
- Publication Part Number: A00076
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A00076 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates four glycols in 15 minutes.
- Publication Part Number: A0161
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00161 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates impurities in propylene glycol in 30 minutes, according to DAB 1995/USP 23.
- Publication Part Number: A01385
- Created: 31 Oct 2011
- 562 KB
Publication Part Number | A01385 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates five fatty acid methyl esters in 20 minutes.
- Publication Part Number: A00090
- Created: 31 Oct 2011
- 625 KB
Publication Part Number | A00090 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates methylisobutylketone and four related compounds in just over four minutes.
- Publication Part Number: A00095
- Created: 31 Oct 2011
- 465 KB
Publication Part Number | A00095 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates 22 food flavors and aromas in 80 minutes.
- Publication Part Number: A00085
- Created: 31 Oct 2011
- 861 KB
Publication Part Number | A00085 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates low concentrations of methanol and dichloromethane in acetone in 10 minutes.
- Publication Part Number: A00002
- Created: 31 Oct 2011
- 306 KB
Publication Part Number | A00002 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates 10 volatile halogenated hydrocarbons and some aromatics in 20 minutes.
- Publication Part Number: A00068
- Created: 31 Oct 2011
- 353 KB
Publication Part Number | A00068 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates 21 alcohols and esters in ‘fire water' in 21 minutes.
- Publication Part Number: A0619
- Created: 31 Oct 2011
- 854 KB
Publication Part Number | A00619 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using split injection and an Agilent J&W CP-Wax 57 CB column separates 26 alcohols and esters in a sample of whisky in 43 minutes.
- Publication Part Number: A00052
- Created: 31 Oct 2011
- 745 KB
Publication Part Number | A00052 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with the AgilentJ&W CP-Wax 57 CB phase separates eight components in an alcoholic beverage in five minutes.
- Publication Part Number: A01907
- Created: 01 Oct 2011
- 580 KB
Publication Part Number | A01907 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|