Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Chemical Group
-
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机GC/MS using an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 25 nitroaromatic standards in 37 minutes.
- Publication Part Number: A01225
- Created: 31 Oct 2011
- 507 KB
Publication Part Number | A01225 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 37 silylated organic acids in urine in 70 minutes.
- Publication Part Number: A01420
- Created: 31 Oct 2011
- 873 KB
Publication Part Number | A01420 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Potentially carcinogenic heterocyclic aromatic amines are formed in small quantities when meat is cooked.必威体育登录手机GC/MS analysis in urine uses an Agilent J&W CP-Sil 8 CB.
- Publication Part Number: A01956
- Created: 31 Oct 2011
- 786 KB
Publication Part Number | A01956 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Due its high specificity, MS/MS offers much more accurate determination of b-damascenone in rose oil, using an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01697
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01697 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 28 silylated organic acids in urine in 70 minutes.
- Publication Part Number: A01421
- Created: 31 Oct 2011
- 819 KB
Publication Part Number | A01421 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 19 pesticides and herbicides according to EPA 507 in 28 minutes.
- Publication Part Number: A1002
- Created: 31 Oct 2011
- 677 KB
Publication Part Number | A01002 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 14 organophosphorus pesticides in 27 minutes.
- Publication Part Number: A01108
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A01108 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS of eight polycyclic aromatic hydrocarbons is accomplished in less than 20 minutes using an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01655
- Created: 31 Oct 2011
- 610 KB
Publication Part Number | A01655 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates seven polar N-herbicides in 25 minutes.
- Publication Part Number: A01111
- Created: 31 Oct 2011
- 425 KB
Publication Part Number | A01111 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS of ten ethyl derivatives of alkylphenols takes less than 18 minutes with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01654
- Created: 31 Oct 2011
- 774 KB
Publication Part Number | A01654 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 15 organochlorine pesticides in 29 minutes.
- Publication Part Number: A01109
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A01109 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS of an adipic ester is achieved in 20 minutes with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01653
- Created: 31 Oct 2011
- 519 KB
Publication Part Number | A01653 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Agilent J&W CP-Sil 8 CB GC columns are ideal for detecting ecstasy by GC/MS.
- Publication Part Number: A02446
- Created: 11 May 2010
- 2 MB
Publication Part Number | A02446 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|