Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 21 phenols according to EPA 8040 in 24 minutes.
- Publication Part Number: A1001
- Created: 31 Oct 2013
- 692 KB
Publication Part Number | A01001 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 15 organochlorine pesticides in 29 minutes.
- Publication Part Number: A01109
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A01109 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS of an adipic ester is achieved in 20 minutes with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01653
- Created: 31 Oct 2011
- 519 KB
Publication Part Number | A01653 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates seven polar N-herbicides in 25 minutes.
- Publication Part Number: A01111
- Created: 31 Oct 2011
- 425 KB
Publication Part Number | A01111 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Potentially carcinogenic heterocyclic aromatic amines are formed in small quantities when meat is cooked.必威体育登录手机GC/MS analysis in urine uses an Agilent J&W CP-Sil 8 CB.
- Publication Part Number: A01956
- Created: 31 Oct 2011
- 786 KB
Publication Part Number | A01956 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS of ten ethyl derivatives of alkylphenols takes less than 18 minutes with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01654
- Created: 31 Oct 2011
- 774 KB
Publication Part Number | A01654 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 14 organophosphorus pesticides in 27 minutes.
- Publication Part Number: A01108
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A01108 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 25 nitroaromatic standards in 37 minutes.
- Publication Part Number: A01225
- Created: 31 Oct 2011
- 507 KB
Publication Part Number | A01225 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 19 pesticides and herbicides according to EPA 507 in 28 minutes.
- Publication Part Number: A1002
- Created: 31 Oct 2011
- 677 KB
Publication Part Number | A01002 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|