Refine Results
- Content Type
-
Content Type
- Chemical Group
-
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 20 light hydrocarbons in 15 minutes.
- Publication Part Number: A0677
- Created: 31 Oct 2011
- 716 KB
Publication Part Number | A00677 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column provides high resolution of 14 C1 to C4 hydrocarbons in seven minutes.
- Publication Part Number: A1095
- Created: 31 Oct 2011
- 561 KB
Publication Part Number | A01095 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 23 C1 to C7 hydrocarbons in natural gas in 50 minutes.
- Publication Part Number: A0271
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00271 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 C1 to C8 light hydrocarbons in natural gas in 20 minutes.
- Publication Part Number: A00226
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A00226 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 C1 to C4 light hydrocarbons in ten minutes.
- Publication Part Number: A0227
- Created: 31 Oct 2011
- 523 KB
Publication Part Number | A00227 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC with Agilent J&W CP-Al2O3/KCl separates C2 to C4 hydrocarbons in a light hydrocarbon stream in 15 minutes, with complete separation at elevated temperature.
- Publication Part Number: A01511
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01511 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 12 C1 to C4 alkanes, alkynes and alkenes in just over 20 minutes.
- Publication Part Number: A00023
- Created: 31 Oct 2011
- 364 KB
Publication Part Number | A00023 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column identifies ten impurities in ethylene in ten minutes.
- Publication Part Number: A01125
- Created: 31 Oct 2011
- 471 KB
Publication Part Number | A01125 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Fast analysis of light hydrocarbons in under 100 s is achieved using a short, 0.53 mm id Agilent J&W CP-Al2O3/KCl PLOT column with micro-volume direct injection.
- Publication Part Number: A01921
- Created: 01 Oct 2011
- 729 KB
Publication Part Number | A01921 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|