必威体育登录手机GC separation of propanal from propylene oxide is achieved in eight minutes using an Agilent J&W PoraBOND U column.
- Publication Part Number: A02049
- Created: 31 Oct 2011
- 389 KB
Publication Part Number | A02049 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 32 solvents in 44 minutes, according to USP 467.
- Publication Part Number: A01546
- Created: 31 Oct 2011
- 892 KB
Publication Part Number | A01546 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column analyzes C3 oxygenated hydrocarbons in less than ten minutes.
- Publication Part Number: A01562
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A01562 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates C2 hydrocarbons to base line in two minutes.
- Publication Part Number: A01587
- Created: 31 Oct 2011
- 382 KB
Publication Part Number | A01587 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 18 solvents in less than 11 minutes.
- Publication Part Number: A01563
- Created: 31 Oct 2011
- 584 KB
Publication Part Number | A01563 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates methyl chloride and dimethyl ether impurities in methanol in less than eight minutes.
- Publication Part Number: A01589
- Created: 31 Oct 2011
- 392 KB
Publication Part Number | A01589 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates hydrochloric acid and water in less than seven minutes, withstanding repeated injections of HCl very well.
- Publication Part Number: A01601
- Created: 31 Oct 2011
- 325 KB
Publication Part Number | A01601 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column produces good peak shapes in the analysis of halogenated hydrocarbons.
- Publication Part Number: A01588
- Created: 31 Oct 2011
- 471 KB
Publication Part Number | A01588 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|