Refine Results
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
- Method
- Language
-
Language
Applied Filters
必威体育登录手机On-site air is monitored for pollutant aromatics using Agilent 490 Micro GC and Agilent J&W CP-Wax 52 CB, separating para- and meta-xylene within 200 s down to ppm.
- Publication Part Number: A01623
- Created: 31 Oct 2011
- 436 KB
Publication Part Number | A01623 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机On-site air is monitored with Agilent 490 Micro GC and Agilent J&W CP-Sil 8 CB.Target components are aromatics, which can be measured within 150 s down to ppm.
- Publication Part Number: A01622
- Created: 31 Oct 2011
- 500 KB
Publication Part Number | A01622 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Select 624 CB column separates 52 C1 to C6 halogenated hydrocarbons and aromatic hydrocarbons in 50 minutes.
- Publication Part Number: A01233
- Created: 31 Oct 2011
- 824 KB
Publication Part Number | A01233 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with Agilent J&W CP-Sil 5 CB and a built-in preconcentration device monitors ozone precursors from containers or directly from sources.
- Publication Part Number: A01640
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01640 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS separation of eight air toxics in a chemical plant is achieved in less than ten minutes with an Agilent J&W Lowox column.
- Publication Part Number: A01652
- Created: 31 Oct 2011
- 759 KB
Publication Part Number | A01652 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 71 halogenated hydrocarbons in water according to EPA 524.5, in 60 minutes.
- Publication Part Number: A1017
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent Pursuit C8 5 µm material in a ChromSep cartridge separates nine aromatic hydrocarbons in 14 minutes.
- Publication Part Number: A02321
- Created: 11 May 2010
- 582 KB
Publication Part Number | A02321 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Performance evaluation of aromatic hydrocarbons determination according to IP391(2000)/ASTM D6591 methods with the Agilent 1260 Infinity Binary LC system with RID
- Publication Part Number: 5991-3170RU
- Created: 24 Mar 2014
- 302 KB
Publication Part Number | 5991-3170EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|