Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Compounds
-
Compounds
- Detection Technique
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates nine nitrosamines according to EPA8270 in less than 20 minutes.
- Publication Part Number: A02091
- Created: 31 Oct 2011
- 402 KB
Publication Part Number | A02091 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC separation of 13 basic aromatic compounds uses the stabilized 50% phenyl PDMS phase of an Agilent VF-17ms column.
- Publication Part Number: A02277
- Created: 31 Oct 2011
- 690 KB
Publication Part Number | A02277 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC separation of nine nitrosamines according to EPA 8270 is achieved in under 20 minutes with the stabilized 50% phenyl PDMS phase in an Agilent VF-17ms column.
- Publication Part Number: A02278
- Created: 31 Oct 2011
- 786 KB
Publication Part Number | A02278 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 51 for Amines column separates nine nitrosamines according to EPA 607 in 18 minutes.
- Publication Part Number: A0785
- Created: 31 Oct 2011
- 493 KB
Publication Part Number | A00785 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC analysis of nine EPA 8270 nitrosamines on a 0.53 mm wide-bore Agilent J&W VF-5ms capillary column takes only 20 minutes.
- Publication Part Number: A02252
- Created: 31 Oct 2011
- 865 KB
Publication Part Number | A02252 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Agilent J&W VF-1701ms columns separate 14 base neutrals in 37 minutes.
- Publication Part Number: A02386
- Created: 11 May 2010
- 712 KB
Publication Part Number | A02386 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Separation of nine nitrosamines using Agilent J&W VF-1701ms in 20 minutes.
- Publication Part Number: A02383
- Created: 11 May 2010
- 759 KB
Publication Part Number | A02383 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of nine nitrosamines by gas chromatography using an Agilent J&W VF-1301ms column in 22 minutes.
- Publication Part Number: A02416
- Created: 11 May 2010
- 627 KB
Publication Part Number | A02416 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机利用創新型安捷倫微吸附采樣器(CTS)、熱分離進樣杆(TSP) 和Agilent 5975T 低熱容氣 質聯用儀(LTM GC/MS) 建立一種測定環境氣體中亞硝胺類化合物的方法。
- Publication Part Number: 5991-1554CHCN
- Created: 08 July 2013
- 275 KB
Publication Part Number | 5991-1554EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|