Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
-
- Method
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent CP-Sil 8 CB column separates ten chlorinated solvents in nine minutes
- Publication Part Number: A00720
- Created: 23 June 2014
- 708 KB
Publication Part Number | A00720 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 19 chlorinated solvents in 12 minutes.
- Publication Part Number: A01415
- Created: 31 Oct 2013
- 501 KB
Publication Part Number | A01415 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The Agilent J&W VF-23ms GC phase is very stable and efficient at lower temperatures, showing high selectivity and inertness for solvent analysis.
- Publication Part Number: A01970
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A01970 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机An Agilent J&W CP-Wax 52 CB column separates 22 solvents by gas chromatography in 40 minutes.
- Publication Part Number: A01952
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A01952 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates five solvents in waste water in seven minutes.
- Publication Part Number: A0668
- Created: 31 Oct 2011
- 526 KB
Publication Part Number | A00668 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Si 5 CB column separates 35 solvents and contaminants in a sample of industrial waste water in 18 minutes.
- Publication Part Number: A01451
- Created: 31 Oct 2011
- 833 KB
Publication Part Number | A01451 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 18 C1 to C11 volatile alcohols, ketones, and ethers in 20 minutes.
- Publication Part Number: A0157
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00157 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 11 amines in 12 minutes.
- Publication Part Number: A01414
- Created: 31 Oct 2011
- 482 KB
Publication Part Number | A01414 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates acrolein, acrylonitrile and acetonitrile according to EPA 8030 in nine minutes.
- Publication Part Number: A0793
- Created: 31 Oct 2011
- 399 KB
Publication Part Number | A00793 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 13 trace C1 to C3 hydrocarbon solvents in drinking water in 11 minutes.
- Publication Part Number: A01423
- Created: 31 Oct 2011
- 878 KB
Publication Part Number | A01423 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine volatile ketones and alcohols in water in 18 minutes.
- Publication Part Number: A0120
- Created: 31 Oct 2011
- 428 KB
Publication Part Number | A00120 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Select 624 CB column separates 53 volatile organic compounds according to EPA 524 in 30 minutes.
- Publication Part Number: A01450
- Created: 31 Oct 2011
- 954 KB
Publication Part Number | A01450 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates ten solvents in five minutes.
- Publication Part Number: A0681
- Created: 31 Oct 2011
- 568 KB
Publication Part Number | A00681 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC/MS with an Agilent J&W CP-Select 624 CB column separates 60 solvents in 16 minutes according to EPA 524.2.
- Publication Part Number: A01255
- Created: 31 Oct 2011
- 764 KB
Publication Part Number | A01255 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 47 solvents and other volatiles according to EPA 8240 in 42 minutes.
- Publication Part Number: A0804
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A00804 | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
必威体育登录手机Gas chromatography using splitless injection with an Agilent J&W PoraBOND Q column separates 17 polar solvents in a water sample in 18 minutes.
- Publication Part Number: A01428
- Created: 31 Oct 2011
- 715 KB
Publication Part Number | A01428 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 19 solvents in 17 minutes.
- Publication Part Number: A0719
- Created: 31 Oct 2011
- 680 KB
Publication Part Number | A00719 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraBOND Q column separates 33 solvents in 30 minutes.
- Publication Part Number: A01624
- Created: 31 Oct 2011
- 579 KB
Publication Part Number | A01624 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机as chromatography using an Agilent J&W CP-Sil 5 CB column separates six solvents in sewage water in 15 minutes.
- Publication Part Number: A0705
- Created: 31 Oct 2011
- 601 KB
Publication Part Number | A00705 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 19 solvents in 30 minutes.
- Publication Part Number: A0718
- Created: 31 Oct 2011
- 862 KB
Publication Part Number | A00718 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|