必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four solvents in a gas mix in 220 seconds.
- Publication Part Number: A0888
- Created: 31 Oct 2013
- 408 KB
Publication Part Number | A00888 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-TCEP for Alcohols in Gasoline column separates six solvents in diisopropylether in 15 minutes.
- Publication Part Number: A00030
- Created: 31 Oct 2011
- 469 KB
Publication Part Number | A00030 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 11 C1 to C6 hydrocarbons and solvents in less than five minutes.
- Publication Part Number: A0670
- Created: 31 Oct 2011
- 620 KB
Publication Part Number | A00670 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select CB for MTBE column separates six solvents in nine minutes.
- Publication Part Number: A0964
- Created: 31 Oct 2011
- 534 KB
Publication Part Number | A00964 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates five solvents in air in 100 seconds.
- Publication Part Number: A00947
- Created: 31 Oct 2011
- 636 KB
Publication Part Number | A00947 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates eight volatile solvents in air in 120 seconds.
- Publication Part Number: A0879
- Created: 31 Oct 2011
- 432 KB
Publication Part Number | A00879 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Application note for the analysis of Volatile Solvents on CP-Sil 5 CB using the Agilent 490 Micro GC
- Publication Part Number: 5990-8699EN
- Created: 25 July 2011
- 254 KB
Publication Part Number | 5990-8699EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|