Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
This application note demonstrates the capabilities of the COX column with the 490 Micro GC.
- Publication Part Number: 5990-7054EN
- Created: 06 Sep 2012
- 610 KB
Publication Part Number | 5990-7054EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Fast GC of five permanent gases and CO2 is achieved in less than three minutes using Agilent PLOT columns in tandem,with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02032
- Created: 31 Oct 2011
- 447 KB
Publication Part Number | A02032 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates helium, hydrogen and nitrogen in 25 seconds.
- Publication Part Number: A0857
- Created: 31 Oct 2011
- 408 KB
Publication Part Number | A00857 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC detects low ppm levels of hydrogen in helium/neon in 30 seconds.
- Publication Part Number: A0864
- Created: 31 Oct 2011
- 255 KB
Publication Part Number | A00864 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Fast GC analysis of permanent gases and CO2 is achieved in two minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02050
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A02050 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC analyzes helium and oxygen impurities in nitrogen in 25 seconds.
- Publication Part Number: A0858
- Created: 31 Oct 2011
- 418 KB
Publication Part Number | A00858 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates hydrogen, oxygen, nitrogen, helium, and neon in 70 seconds.
- Publication Part Number: A0860
- Created: 31 Oct 2011
- 374 KB
Publication Part Number | A00860 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates helium, oxygen, nitrogen, methane, hydrogen, and carbon monoxide in 70 s.
- Publication Part Number: A0870
- Created: 31 Oct 2011
- 352 KB
Publication Part Number | A00870 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Analysis of permenant gases using 10m Molsieve column for samples with a high % of oxygen.
- Publication Part Number: 5990-8527EN
- Created: 05 July 2011
- 340 KB
Publication Part Number | 5990-8527EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|