Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
A gas chromatography method has been developed for the analysis of natural gas and natural gas liquids by capillary column
- Publication Part Number: 5991-2063eN
- Created: 20 Mar 2013
- 183 KB
Publication Part Number | 5991-2063EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
This application note demonstrates the capabilities of the COX column with the 490 Micro GC.
- Publication Part Number: 5990-7054EN
- Created: 06 Sep 2012
- 610 KB
Publication Part Number | 5990-7054EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates six permanent gases in six minutes.
- Publication Part Number: A01245
- Created: 31 Oct 2011
- 394 KB
Publication Part Number | A01245 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates five permanent gases in less than three minutes.
- Publication Part Number: A01246
- Created: 31 Oct 2011
- 434 KB
Publication Part Number | A01246 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates six permanent gases in eight minutes.
- Publication Part Number: A01247
- Created: 31 Oct 2011
- 467 KB
Publication Part Number | A01247 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin-film Agilent J&W CP-Molsieve column separates four permanent gases in five minutes.
- Publication Part Number: A01248
- Created: 31 Oct 2011
- 477 KB
Publication Part Number | A01248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates four permanent gases in five minutes.
- Publication Part Number: A01249
- Created: 31 Oct 2011
- 395 KB
Publication Part Number | A01249 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates five gases in five minutes.
- Publication Part Number: A0307
- Created: 31 Oct 2011
- 368 KB
Publication Part Number | A00307 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC of five permanent gases and CO2 is achieved in less than three minutes using Agilent PLOT columns in tandem,with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02032
- Created: 31 Oct 2011
- 447 KB
Publication Part Number | A02032 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of permanent gases and CO2 is achieved in two minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02050
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A02050 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CarboBOND column analyzes carbon dioxide and carbon monoxide in hydrocarbon streams in six minutes.
- Publication Part Number: A01431
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A01431 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates carbon monoxide, carbon dioxide and other gases in air in five minutes.
- Publication Part Number: A0494
- Created: 31 Oct 2011
- 510 KB
Publication Part Number | A00494 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Separation of hydrogen and helium by GC on an Agilent J&W CP-Molsieve column in 7.5 minutes.
- Publication Part Number: A02077
- Created: 31 Oct 2011
- 695 KB
Publication Part Number | A02077 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Molsieve 5Å column separates six permanent gases in 20 minutes.
- Publication Part Number: A0764
- Created: 31 Oct 2011
- 529 KB
Publication Part Number | A00764 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Molsieve 5Å column determines deuterated hydrogen in five minutes.
- Publication Part Number: A0761
- Created: 31 Oct 2011
- 425 KB
Publication Part Number | A00761 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates four gases in five minutes.
- Publication Part Number: A0683
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00683 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column separates ethane, D6-ethane and other C2 hydrocarbons in 78 minutes.
- Publication Part Number: A0274
- Created: 31 Oct 2011
- 414 KB
Publication Part Number | A00274 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates five gases in four minutes.
- Publication Part Number: A0294
- Created: 31 Oct 2011
- 372 KB
Publication Part Number | A00294 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates oxygen, nitrogen, carbon monoxide and other gases in air in four minutes.
- Publication Part Number: A0495
- Created: 31 Oct 2011
- 486 KB
Publication Part Number | A00495 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|