Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
- Detection Technique
- Injection Technique
- Language
-
Language
Applied Filters
Application note for the multi-residue analysis for PAHs, PCBs and OCPs on FactorFour VF-200ms
- Publication Part Number: SI-02467
- Created: 30 Jan 2014
- 348 KB
Publication Part Number | SI-02467 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for the multi-residue analysis of PAHs, PCBs and OCPs using an Agilent FactorFour VF-35ms Column
- Publication Part Number: SI-2396
- Created: 30 Jan 2014
- 274 KB
Publication Part Number | SI-02396 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Multi-residue analysis of PAHs, PCBs and OCPs was performed using GC/MS with Agilent J&W FactorFour VF-Xms column, demonstrating separation
- Publication Part Number: SI-02443
- Created: 09 Aug 2013
- 302 KB
Publication Part Number | SI-02443 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Polycyclic aromatic hydrocarbons (PAHs) are often analyzed with other environmental pollutants, such as polychlorinated...
- Publication Part Number: SI-2438
- Created: 09 July 2013
- 458 KB
Publication Part Number | SI-02438 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Multi-residue analysis of PAHs, PCBs and OCPs in environmental samples using a GC-MS with a FactorFour VF-5ms column and quadrupole MS.
- Publication Part Number: SI-2364
- Created: 26 Sep 2012
- 167 KB
Publication Part Number | SI-02364 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an AgilentJ&W CP-Sil 19 CB column separates 30 organochlorine pesticides in 59 minutes.
- Publication Part Number: A1094
- Created: 31 Oct 2011
- 679 KB
Publication Part Number | A01094 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 29 pesticides according to EPA 508 in 64 minutes.
- Publication Part Number: A0780
- Created: 31 Oct 2011
- 551 KB
Publication Part Number | A00780 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A00805 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 19 CB column separates 21organochlorine pesticides in 40 minutes.
- Publication Part Number: A00055
- Created: 31 Oct 2011
- 780 KB
Publication Part Number | A00055 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 19 organochlorine pesticides according to EPA 8080 in 50 minutes.
- Publication Part Number: A0796
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00796 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 60 pesticides and polycyclic biphenyls in 24 minutes.
- Publication Part Number: A0709
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00709 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|