Refine Results
- 必威体育赛事投注
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column identifies 12 aromas in a lily plant in 40 minutes.
- Publication Part Number: A1010
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A01010 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates seven C1 to C5 acetates in five minutes.
- Publication Part Number: A00007
- Created: 31 Oct 2011
- 321 KB
Publication Part Number | A00007 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates C3 to C7 hydrocarbons in a sample of naphtha in 60 minutes.
- Publication Part Number: A0165
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A00165 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates ten phthalate esters in a plastic toy in 30 minutes.
- Publication Part Number: A01462
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01462 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column produces a fingerprint of C2 to C20 hydrocarbons in exhaust gas in 55 minutes.
- Publication Part Number: A0412
- Created: 31 Oct 2011
- 636 KB
Publication Part Number | A00412 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column uses on line analysis to identify diethylene glycol in monoethylene glycol in three minutes.
- Publication Part Number: A0657
- Created: 31 Oct 2011
- 449 KB
Publication Part Number | A00657 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column produces a fingerprint of trace volatiles in polycarbonate in 50 minutes.
- Publication Part Number: A0411
- Created: 31 Oct 2011
- 944 KB
Publication Part Number | A00411 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates nine C6 to C9 aromatic impurities in styrene in 25 minutes.
- Publication Part Number: A0151
- Created: 31 Oct 2011
- 680 KB
Publication Part Number | A00151 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a 0.15 mm id Agilent J&W CP-Sil 5 CB column separates residual solvents in less than seven minutes.
- Publication Part Number: A01502
- Created: 31 Oct 2011
- 788 KB
Publication Part Number | A01502 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Boiling point analysis of sulfur compounds in kerosene (jet fuel) by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01813
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01813 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Boiling point analysis of sulfur compounds in cracked gasoil by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01811
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01811 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Boiling point analysis of sulfur compounds in hydrogenated naphtha by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01812
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01812 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
MS
- Publication Part Number: 5990-8069EN
- Created: 02 June 2011
- 462 KB
Publication Part Number | 5990-8069EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Acids can be analyzed on thick-film non-polar phases such as Agilent J&W CP-Sil 5 CB.
- Publication Part Number: A02435
- Created: 11 May 2010
- 417 KB
Publication Part Number | A02435 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Acids can be analyzed on thick-film non-polar phases such as Agilent J&W CP-Sil 5 CB, though lactic acid and derivatives can overload rapidly, deforming peak shape.
- Publication Part Number: A02436
- Created: 11 May 2010
- 453 KB
Publication Part Number | A02436 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|