Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Chemical Group
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 13 halogenated hydrocarbons in land fill gas in 28 minutes.
- Publication Part Number: A0300
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A00300 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates nine volatile halogen compounds in a water sample.
- Publication Part Number: A00062
- Created: 31 Oct 2011
- 691 KB
Publication Part Number | A00062 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with Agilent J&W CP-Sil 8 CB and CP- 5 CB columns separate 33 methyl-, nitro, and chlorophenols in river water in 35 minutes.
- Publication Part Number: A0339
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00339 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates eight C1 to C2 halogenated hydrocarbons in air in 20 minutes.
- Publication Part Number: A1012
- Created: 31 Oct 2011
- 476 KB
Publication Part Number | A01012 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates four hexachlorocyclohexane isomers in 10 minutes.
- Publication Part Number: A00070
- Created: 31 Oct 2011
- 369 KB
Publication Part Number | A00070 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 30 polychlorinated biphenyls in 65 minutes.
- Publication Part Number: A0916
- Created: 31 Oct 2011
- 820 KB
Publication Part Number | A00916 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|