Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
- Detection Technique
-
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机Application note for the analysis of Pesticide Residues in Apple by GC/MS using Agilent Bond Elut QuEChERS Kits for Preinjection Cleanup
- Publication Part Number: 5990-4468EN
- Created: 06 Jan 2012
- 217 KB
Publication Part Number | 5990-4468EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 25 organophosphorus pesticides according to EPA 8140 and 8141 in 31 minutes.
- Publication Part Number: A0615
- Created: 31 Oct 2011
- 867 KB
Publication Part Number | A00615 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 27 polar pesticides in 25 minutes.
- Publication Part Number: A01352
- Created: 31 Oct 2011
- 969 KB
Publication Part Number | A01352 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates nine organophosphate pesticides in 15 minutes.
- Publication Part Number: A0358
- Created: 31 Oct 2011
- 695 KB
Publication Part Number | A00358 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 14 organophosphorus pesticides in 27 minutes.
- Publication Part Number: A01108
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A01108 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separate 58 organophosphorus pesticides in 26 minutes.
- Publication Part Number: A01348
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A01348 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC with Agilent J&W CP-Sil 8 CB and PFPD is a highly sensitive and selective system capable of detecting a number of elements, 13 of these with ultimate selectivity.
- Publication Part Number: A01608
- Created: 31 Oct 2011
- 4 MB
Publication Part Number | A01608 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Fast GC analysis of 25 pesticides using splitless injection on a 0.15 mm id Agilent J&W CP-Sil 13 CB column.
- Publication Part Number: A02239
- Created: 31 Oct 2011
- 633 KB
Publication Part Number | A02239 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 19 pesticides and herbicides according to EPA 507 in 37 minutes.
- Publication Part Number: A0911
- Created: 31 Oct 2011
- 719 KB
Publication Part Number | A00911 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 19 pesticides and herbicides according to EPA 507 in 28 minutes.
- Publication Part Number: A1002
- Created: 31 Oct 2011
- 677 KB
Publication Part Number | A01002 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 19 pesticides and herbicides according to EPA 507 in 23 minutes.
- Publication Part Number: A00779
- Created: 31 Oct 2011
- 638 KB
Publication Part Number | A00779 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Sil 24 CB Low Bleed/MS column delivers highly selective trace analysis of 23 pesticide residues in surface water in 23 minutes.
- Publication Part Number: A01503
- Created: 31 Oct 2011
- 809 KB
Publication Part Number | A01503 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast analysis of pesticides in an apple matrix is achieved by gas chromatography with an Agilent J&W CP-Sil 13 CB column and splitless injection.
- Publication Part Number: A02382
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02382 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast analysis of 23 pesticides is straightforward by gas chromatography with an Agilent J&W CP-Sil 13 CB column and splitless injection.
- Publication Part Number: A02381
- Created: 11 May 2010
- 575 KB
Publication Part Number | A02381 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The Agilent J&W VF-5ms GC column separates 51 pesticide residues in vegetable samples in 38 minutes.
- Publication Part Number: A02441
- Created: 11 May 2010
- 671 KB
Publication Part Number | A02441 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|