Method development for QuEChERS sample preparation is used to extract pesticide residues in highly variable concentrated fruit juices, followed by GC/MS/MS
- Publication Part Number: 5991-3342EN
- Created: 21 Oct 2013
- 6 MB
Publication Part Number | 5991-3342EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机The Agilent Inert Flow Path outperformed a non-Agilent version for trace pesticides, with less impact on analytes and better results for some critical pesticides.
- Publication Part Number: 5991-3234EN
- Created: 19 Sep 2013
- 925 KB
Publication Part Number | 5991-3234EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Agilent Ultra Inert liners with wool give accurate and precise pesticide trace levels from 5 µL extracts in acetonitrile.
- Publication Part Number: 5991-1196EN
- Created: 04 Oct 2012
- 1 MB
Publication Part Number | 5991-1196EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of Pesticide Residues in Spinach Using Agilent Bond Elut QuEChERS AOAC Kits by GC/MS
- Publication Part Number: 5990-4305EN
- Created: 06 Jan 2012
- 1,000 KB
Publication Part Number | 5990-4305EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|
必威体育登录手机Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS EN Kits by GC/MS
- Publication Part Number: 5990-4073EN
- Created: 06 Jan 2012
- 777 KB
Publication Part Number | 5990-4073EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|
必威体育登录手机Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS AOAC Kits by GC/MS
- Publication Part Number: 5990-4068EN
- Created: 06 Jan 2012
- 113 KB
Publication Part Number | 5990-4068EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|