Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机Small –scale purification of a monoclonal antibody from a cell lysate and the subsequent analysis on a single instrument, the Agilent 1260 Infinity Bio-inert Quaternary LC.
- Publication Part Number: 5991-1195EN
- Created: 01 May 2016
- 854 KB
Publication Part Number | 5991-1195EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机This Application Note describes the quantification of human IgG with the Agilent Bio-Monolith Protein A HPLC Column with alternating column regeneration.
- Publication Part Number: 5991-4723EN
- Created: 01 June 2014
- 836 KB
Publication Part Number | 5991-4723EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
In this application note, pre-packed Bio-monolith Protein A columns, part of the AdvanceBio family, were used to demonstrate the quick capture of monoclonal antibody titer
- Publication Part Number: 5991-2990EN
- Created: 08 Jan 2014
- 441 KB
Publication Part Number | 5991-2990EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
This Application Note describes an application solution for the removal and monitoring of genomic DNA contamination from monoclonal antibody preparation.
- Publication Part Number: 5991-3527EN
- Created: 01 Nov 2013
- 987 KB
Publication Part Number | 5991-3527EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
This shows the separation of four proteins by anion exchange chromatography using 4 different high salt-containing elution buffers (up to 2 M) for linear and step gradients.
- Publication Part Number: 5990-9614EN
- Created: 01 Aug 2013
- 658 KB
Publication Part Number | 5990-9614EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Columns containing weak cation-exchange stationary phases offer a degree of versability when used for separation of positively charged proteins.
- Publication Part Number: 5990-9628EN
- Created: 01 Aug 2013
- 1 MB
Publication Part Number | 5990-9628EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Ion exchange is a commonly used technique for the separation of complex protein mixtures.
- Publication Part Number: 5990-9931EN
- Created: 01 Aug 2013
- 2 MB
Publication Part Number | 5990-9931EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Methods are given for the use of Agilent Bio-SEC columns, with LS, UV and RI detection, for quantification or quality control of protein aggregates
- Publication Part Number: 5991-1400EN
- Created: 07 Jan 2013
- 284 KB
Publication Part Number | 5991-1400EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机This Application Note describes a high-resolution, pH-based separation of acidic and basic charge variants for monoclonal antibodies using the Agilent 1260 and BiomAb PEEK
- Publication Part Number: 5991-1407EN
- Created: 01 Dec 2012
- 805 KB
Publication Part Number | 5991-1407EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
本應用簡報報導了一種簡易的反相 HPLC 方法,用於分析單克隆抗體 (mAb) 中的二硫鍵。
- Publication Part Number: 5991-1694CHCN
- Created: 01 Feb 2013
- 1 MB
Publication Part Number | 5991-1694EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
pH 梯度洗脫用於改善單克隆抗體帶電變體的分離
- Publication Part Number: 5990-9629CHCN
- Created: 16 Dec 2011
- 584 KB
Publication Part Number | 5990-9629EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|