Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column separates 14 amines in 40 minutes to demonstrate the linearity of amine elution.
- Publication Part Number: A01275
- Created: 31 Oct 2011
- 554 KB
Publication Part Number | A01275 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-1301 column separates ten components in a test mixture in 12 minutes.
- Publication Part Number: A01221
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A01221 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 13 C10 to C16 alkanes in 15 minutes.
- Publication Part Number: A00087
- Created: 31 Oct 2011
- 659 KB
Publication Part Number | A00087 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column determines trace levels of amines in 25 minutes.
- Publication Part Number: A01278
- Created: 31 Oct 2011
- 577 KB
Publication Part Number | A01278 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 13 CB column separates 12 components in the Grob test mixture in 45 minutes.
- Publication Part Number: A01222
- Created: 31 Oct 2011
- 452 KB
Publication Part Number | A01222 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-1301 column separates 11 components in the Grob test mixture in 47 minutes.
- Publication Part Number: A01223
- Created: 31 Oct 2011
- 440 KB
Publication Part Number | A01223 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 51 for Amines column separates nine volatile amines in 20 minutes.
- Publication Part Number: A00089
- Created: 31 Oct 2011
- 448 KB
Publication Part Number | A00089 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column separates ten C4 to C12 amines in 30 minutes.
- Publication Part Number: A01253
- Created: 31 Oct 2011
- 560 KB
Publication Part Number | A01253 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 51 for Amines column separates six alkylamines and aromatic amines in six minutes.
- Publication Part Number: A0698
- Created: 31 Oct 2011
- 571 KB
Publication Part Number | A00698 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
1290 Infinity DAD with Max-Light Cartridge High Sensitivity Cell for purity analysis in drug development and quality control.
- Publication Part Number: 5990-7443EN
- Created: 01 Mar 2011
- 575 KB
Publication Part Number | 5990-7443EN | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||||||
Instrument |
|
||||||||||
Analytical Technique | Technique |
|
|||||||||
Injection |
|
||||||||||
Detection |
|
||||||||||
Sample | Chemical Group |
|
|||||||||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
485B.jpg
- Publication Part Number: 880975-902
- Created: 08 May 2018
- 52 KB
- JPG
Publication Part Number | 485B | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|