必威体育登录手机Performance of the Agilent 1260 Infinity Binary LC System for the measurement of components in coffee and coffee products according to DIN methods in Food Testing
- Publication Part Number: 5991-2853EN
- Created: 01 Sep 2016
- 591 KB
Publication Part Number | 5991-2853EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of tocopherols and tocotrienols in virgin olive oil using the Agilent 1260 Infinity Bio-inert Quaternary LC system with fluorescence detection.
- Publication Part Number: 5991-2180EN
- Created: 01 May 2016
- 619 KB
Publication Part Number | 5991-2180EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Methods separating anthocyanins compounds originally developed on Agilent ZORBAX StableBond SB-C18 columns are transferred to an Agilent Poroshell 120 SB-C18 column.
- Publication Part Number: 5990-8249EN
- Created: 08 Dec 2015
- 505 KB
Publication Part Number | 5990-8249EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Demostration that stringent sensitivity requirements for the detection of potentially harmful primary aromatic amines can be fulfilled.
- Publication Part Number: 5990-9751EN
- Created: 15 Sep 2014
- 487 KB
Publication Part Number | 5990-9751EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Comprehensive 2D-LC using the Agilent 1290 Infinity 2D-LC Solution with DAD and MS detection is applied for the analysis of citrus oils.
- Publication Part Number: 5991-3474EN
- Created: 15 Sep 2014
- 1 MB
Publication Part Number | 5991-3474EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机This Application Note describes the analysis of hydrophilic phenolic compounds in olive oil samples, using both HPLC and UHPLC with ternary gradients on the Agilent 1260 Infin
- Publication Part Number: 5991-3801EN
- Created: 01 May 2014
- 836 KB
Publication Part Number | 5991-3801EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Demonstration of the Agilent 1290 Infinity 2D-LC Solution to resolve the hydrophilic phenols in virgin olive oils and investigation of differences between olive oils.
- Publication Part Number: 5991-4515EN
- Created: 01 May 2014
- 3 MB
Publication Part Number | 5991-4515EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
This method reduced solvent consumption and increased peak resolution, vs.the existing method, for Vitamin A palmitate and beta-carotene in nutritional supplements.
- Publication Part Number: 5991-4385EN
- Created: 25 Apr 2014
- 758 KB
Publication Part Number | 5991-4385EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Poroshell 120 PFP gives extra retention and selectivity of halogenate positional isomers, enhanced with functional groups on aromatic or other rigid ring systems.
- Publication Part Number: 5991-4373EN
- Created: 03 Apr 2014
- 306 KB
Publication Part Number | 5991-4373EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机The Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector solution expands the linear dynamic range for UHPLC detection by a factor of 30.
- Publication Part Number: 5991-3876EN
- Created: 01 Mar 2014
- 4 MB
Publication Part Number | 5991-3876EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Application note for the high resolution separations by Supercritical Fluid Chromatography Using a Coupled Column Approach
- Publication Part Number: 5990-6934EN
- Created: 03 Feb 2014
- 276 KB
Publication Part Number | 5990-6934EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Agilent Captiva Premium regenerated-cellulose syringe filters are excellent for beverage additive analysis, with excellent recovery and particulate removal efficiency.
- Publication Part Number: 5991-3737EN
- Created: 12 Dec 2013
- 465 KB
Publication Part Number | 5991-3737EN | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||||
Instrument |
|
|||||||||
Analytical Technique | Technique |
|
||||||||
Injection |
|
|||||||||
Detection |
|
|||||||||
Sample | Chemical Group |
|
||||||||
Sample Matrix |
|
必威体育登录手机Analysis of squalene in olive oil samples with HPLC and UHPLC methods using the Agilent 1220 Infinity Mobile LC Solution.
- Publication Part Number: 5991-2774EN
- Created: 01 Aug 2013
- 322 KB
Publication Part Number | 5991-2774EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of counterfeit antidiabetic sulfonylurea-class drugs using Agilent 1220 Infinity Gradient LC with diode array detector.
- Publication Part Number: 5991-2177EN
- Created: 01 Apr 2013
- 693 KB
Publication Part Number | 5991-2177EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育赛事投注Sample cleanup of alkaloids of Goldenseal commercial products (hydrastine and berberine) was achieved by SPE employing SampliQ Optimized Polymer Technology (OPT) sorbents.
- Publication Part Number: 5990-4188EN
- Created: 06 Mar 2013
- 542 KB
Publication Part Number | 5990-4188EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of 3,5-stigmastadienes olive oil samples using the Agilent 1220 Infinity Mobile LC Solution.
- Publication Part Number: 5991-1894EN
- Created: 01 Mar 2013
- 540 KB
Publication Part Number | 5991-1894EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
This describes a rapid & precise HPLC procedure for quantitative determination of organic acids in fruit juices under reversed-phase conditions with a100% aqueous mobile phase
- Publication Part Number: 5991-1992EN
- Created: 20 Feb 2013
- 580 KB
Publication Part Number | 5991-1992EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Complementary SFC and UHPLC analysis of antioxidants in vegetable oil samples using the 1260 Infinity Hybrid SFC/UHPLC System with mass spectrometry detection.
- Publication Part Number: 5991-1546EN
- Created: 15 Feb 2013
- 2 MB
Publication Part Number | 5991-1546EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机2-Dimensional LC analysis of beer samples using the Agilent 1290 Infinity 2D-LC system.
- Publication Part Number: 5991-1601EN
- Created: 01 Feb 2013
- 1 MB
Publication Part Number | 5991-1601EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
This Application Note shows the emulation of the Waters Alliance 2695.
- Publication Part Number: 5991-1604EN
- Created: 01 Jan 2013
- 951 KB
Publication Part Number | 5991-1604EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|