Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
- Detection Technique
-
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
The sensitivity of UHPLC/MS method on an 6150 Series Single Quadrupole LC/MS was demonstrated for the application of cleaning verification studies of highly potent drugs.
- Publication Part Number: 5991-4509EN
- Created: 01 June 2014
- 1 MB
Publication Part Number | 5991-4509EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates four tricyclic antidepressants in ten minutes.
- Publication Part Number: A0159
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00159 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 24 CB column separates eight tricyclic antidepressants in 46 minutes.
- Publication Part Number: A1003
- Created: 31 Oct 2011
- 562 KB
Publication Part Number | A01003 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 13 tricyclic antidepressants in plasma in 14 minutes.
- Publication Part Number: A0245
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00245 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机HPLC using an Agilent Polaris C18-A column separates seven tricyclic antidepressants in 16 minutes.
- Publication Part Number: A01937
- Created: 01 Oct 2011
- 602 KB
Publication Part Number | A01937 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Application note for Solid phase extraction of basic drugs in plasma with Agilent Bond Elut Plexa
- Publication Part Number: 5990-7685EN
- Created: 21 Mar 2011
- 104 KB
Publication Part Number | 5990-7685EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机HPLC separation of eight antidepressants is easy on Agilent Pursuit C8 5 µm material in a ChromSep cartridge, with results in 30 minutes.
- Publication Part Number: A02319
- Created: 11 May 2010
- 455 KB
Publication Part Number | A02319 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
A mixed mode polymer is an effective way to analyze multiple drug classes in a single plasma sample.
- Publication Part Number: SI-01014
- Created: 10 July 2014
- 144 KB
Publication Part Number | SI-01014 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|