Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent CP-Sil 8 CB column separates ten chlorinated solvents in nine minutes
- Publication Part Number: A00720
- Created: 23 June 2014
- 708 KB
Publication Part Number | A00720 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 19 chlorinated solvents in 12 minutes.
- Publication Part Number: A01415
- Created: 31 Oct 2013
- 501 KB
Publication Part Number | A01415 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 organic solvents in 35 minutes.
- Publication Part Number: A0493
- Created: 31 Oct 2011
- 671 KB
Publication Part Number | A00493 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Select 624 CB column separates 53 volatile organic compounds according to EPA 524 in 30 minutes.
- Publication Part Number: A01450
- Created: 31 Oct 2011
- 954 KB
Publication Part Number | A01450 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC/MS with an Agilent J&W CP-Select 624 CB column separates 60 solvents in 16 minutes according to EPA 524.2.
- Publication Part Number: A01255
- Created: 31 Oct 2011
- 764 KB
Publication Part Number | A01255 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 47 solvents and other volatiles according to EPA 8240 in 42 minutes.
- Publication Part Number: A0804
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A00804 | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 19 solvents in 17 minutes.
- Publication Part Number: A0719
- Created: 31 Oct 2011
- 680 KB
Publication Part Number | A00719 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|