必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column and Agilent 490 Micro GC separates C1 to C4 hydrocarbons in 100 seconds.
- Publication Part Number: A02067
- Created: 31 Oct 2011
- 393 KB
Publication Part Number | A02067 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q column separates 11 C1 to C6 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0607
- Created: 31 Oct 2011
- 639 KB
Publication Part Number | A00607 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 31components in unleaded gasoline according to ASTM D5769 in 58 minutes.
- Publication Part Number: A01274
- Created: 31 Oct 2011
- 874 KB
Publication Part Number | A01274 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 21 light hydrocarbons in 30 minutes.
- Publication Part Number: A01454
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A01454 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 111components during naphtha and reformate according to ASTM D5134 in 75 minutes.
- Publication Part Number: A0752
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00752 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 39 C1 to C4 nitriles and C1 to C5 hydrocarbons in 60 minutes.
- Publication Part Number: A00572
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00572 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column separates 20 C1 to C6 hydrocarbons in a reference mixture in 15 minutes.
- Publication Part Number: A01123
- Created: 31 Oct 2011
- 565 KB
Publication Part Number | A01123 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 15 C1 to C4 light hydrocarbons in eight minutes.
- Publication Part Number: A0253
- Created: 31 Oct 2011
- 463 KB
Publication Part Number | A00253 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 22 saturated and unsaturated light hydrocarbons in 20 minutes.
- Publication Part Number: A00037
- Created: 31 Oct 2011
- 480 KB
Publication Part Number | A00037 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column indentifies 13 C1 to C6 hydrocarbon impurities in 1,3-butadiene in 15 minutes.
- Publication Part Number: A01121
- Created: 31 Oct 2011
- 535 KB
Publication Part Number | A01121 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 C1 to C5 hydrocarbons and hydrogen sulfide in fuel gas in 16 minutes.
- Publication Part Number: A00574
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00574 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column resolves 14 C1 to C6 hydrocarbon impurities in propylene in 20 minutes.
- Publication Part Number: A01097
- Created: 31 Oct 2011
- 613 KB
Publication Part Number | A01097 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 15 C1 to C6 hydrocarbon impurities in cis-2-butene in 20 minutes.
- Publication Part Number: A01100
- Created: 31 Oct 2011
- 550 KB
Publication Part Number | A01100 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates eight C1 to C4 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0606
- Created: 31 Oct 2011
- 575 KB
Publication Part Number | A00606 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 24 C1 to C5 hydrocarbons in 27 minutes.
- Publication Part Number: A0611
- Created: 31 Oct 2011
- 957 KB
Publication Part Number | A00611 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 components in a sample of liquid petroleum gas in three minutes.
- Publication Part Number: A00038
- Created: 31 Oct 2011
- 582 KB
Publication Part Number | A00038 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 17 impurities in high purity propylene in 34 minutes.
- Publication Part Number: A01312
- Created: 31 Oct 2011
- 796 KB
Publication Part Number | A01312 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|