必威体育登录手机This application note describes the use of an Agilent Micro GC for gas composition analysis during fuel cell research and development and beta testing.
- Publication Part Number: 5991-3364EN
- Created: 01 Dec 2014
- 332 KB
Publication Part Number | 5991-3364EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机This application note describes the use of the Agilent 490-PRO Micro GC for the analysis of liquefied ethane product.
- Publication Part Number: 5991-1817EN
- Created: 25 Jan 2013
- 527 KB
Publication Part Number | 5991-1817EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
Gas chromatography is a proven technology to analyze natural gas and its impurities.
- Publication Part Number: 5991-1190EN
- Created: 18 Dec 2012
- 692 KB
Publication Part Number | 5991-1190EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
490-GC can be used for analyses of mine gas, especially carbon monoxide at low level which is essential for the safety of mine workers.
- Publication Part Number: SI-02235
- Created: 06 Sep 2012
- 642 KB
Publication Part Number | SI-02235 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机This application note describes a method for fast on-site analysis of mine gases in less than 100 seconds using the Agilent 490 Micro GC.
- Publication Part Number: 5991-0438EN
- Created: 06 June 2012
- 753 KB
Publication Part Number | 5991-0438EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机This application note shows the analysis of biogas, and related samples, using the Agilent 490 Micro GC Biogas Analyzer.
- Publication Part Number: 5990-9508EN
- Created: 22 Nov 2011
- 253 KB
Publication Part Number | 5990-9508EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|---|
Korean (Korea) | Complete (PDF) |
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC separates halogenated hydrocarbons in air in 250 seconds.
- Publication Part Number: A01340
- Created: 31 Oct 2011
- 573 KB
Publication Part Number | A01340 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in a chlor-alkali cell in 60 seconds.
- Publication Part Number: A02064
- Created: 31 Oct 2011
- 729 KB
Publication Part Number | A02064 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates acetylene, ethylene, ethane, and carbon dioxide in air in 28 seconds.
- Publication Part Number: A0892
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A00892 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with a four-channel Agilent 490 Micro GC separates constituents of mine gas, including carbon monoxide, in 120 seconds.
- Publication Part Number: A01789
- Created: 31 Oct 2011
- 614 KB
Publication Part Number | A01789 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four gases in air in 22 seconds.
- Publication Part Number: A00887
- Created: 31 Oct 2011
- 530 KB
Publication Part Number | A00887 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in 25 seconds.
- Publication Part Number: A02065
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A02065 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates methane, ethylene, ethane, and carbon dioxide in air in 28 seconds.
- Publication Part Number: A0891
- Created: 31 Oct 2011
- 401 KB
Publication Part Number | A00891 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Four-channel Agilent 490 Micro GC analyzes refinery gas, permanent gases, hydrogen sulfide, and all saturated and unsaturated hydrocarbons up to C5, in 150 s.
- Publication Part Number: A01786
- Created: 31 Oct 2011
- 810 KB
Publication Part Number | A01786 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GCwith an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates methane, propane, ethane, and carbon dioxide in natural gas in 70 seconds.
- Publication Part Number: A0890
- Created: 31 Oct 2011
- 364 KB
Publication Part Number | A00890 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-AL2O3/KCl column module and Agilent 490 Micro GC separates 14 C1 to C4 hydrocarbons in 200 seconds.
- Publication Part Number: A0906
- Created: 31 Oct 2011
- 675 KB
Publication Part Number | A00906 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机This application note shows the possibilities and limitations in fast analysis of saturated and unsaturated C1 to C3 hydrocarbons using an Agilent 490 Micro GC.
- Publication Part Number: 5990-9165EN
- Created: 04 Oct 2011
- 320 KB
Publication Part Number | 5990-9165EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|