必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C5 hydrocarbons in exhaust from a gasoline engine in 42 minutes.
- Publication Part Number: A00739
- Created: 31 Oct 2011
- 765 KB
Publication Part Number | A00739 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C3 to C4 impurities in 1,2-butadiene in 20 minutes.
- Publication Part Number: A00594
- Created: 31 Oct 2011
- 774 KB
Publication Part Number | A00594 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Al2O3/Na2SO4 column separates C2 to C4 hydrocarbons in a light hydrocarbon stream in 27 minutes, with complete separation at elevated temperature.
- Publication Part Number: A01512
- Created: 31 Oct 2011
- 840 KB
Publication Part Number | A01512 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A01505 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 18 saturated and unsaturated C1 to C6 hydrocarbons in seven minutes.
- Publication Part Number: A0121
- Created: 31 Oct 2011
- 616 KB
Publication Part Number | A00121 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column separates 20 C1 to C6 hydrocarbons in a reference mixture in 15 minutes.
- Publication Part Number: A01123
- Created: 31 Oct 2011
- 565 KB
Publication Part Number | A01123 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten impurities in propylene in 14 minutes.
- Publication Part Number: A0714
- Created: 31 Oct 2011
- 601 KB
Publication Part Number | A00714 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column provides high resolution of 14 C1 to C4 hydrocarbons in seven minutes.
- Publication Part Number: A1095
- Created: 31 Oct 2011
- 561 KB
Publication Part Number | A01095 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column resolves 14 C1 to C6 hydrocarbon impurities in propylene in 20 minutes.
- Publication Part Number: A01097
- Created: 31 Oct 2011
- 613 KB
Publication Part Number | A01097 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-SilicaPLOT column separates cyclopropane in propylene in 15 minutes.
- Publication Part Number: A01261
- Created: 31 Oct 2011
- 518 KB
Publication Part Number | A01261 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 39 C1 to C4 nitriles and C1 to C5 hydrocarbons in 60 minutes.
- Publication Part Number: A00572
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00572 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 C1 to C9 hydrocarbons and C6 to C9 aromatics in 40 minutes.
- Publication Part Number: A0604
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A00604 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates nine saturated and unsaturated C3 to C4 hydrocarbons in four minutes.
- Publication Part Number: A00027
- Created: 31 Oct 2011
- 529 KB
Publication Part Number | A00027 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of C1 to C4 hydrocarbons is achieved in 15 minutes using the Agilent J&W Select Al2O3 MAPD.
- Publication Part Number: A02042
- Created: 31 Oct 2011
- 990 KB
Publication Part Number | A02042 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 components in a sample of liquid petroleum gas in three minutes.
- Publication Part Number: A00038
- Created: 31 Oct 2011
- 582 KB
Publication Part Number | A00038 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column separates 10 C3 to C6 hydrocarbons in 12 minutes.
- Publication Part Number: A01298
- Created: 31 Oct 2011
- 730 KB
Publication Part Number | A01298 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates ten C3 to C4 impurities in cis-2-butene in 12 minutes.
- Publication Part Number: A00593
- Created: 31 Oct 2011
- 695 KB
Publication Part Number | A00593 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-AL2O3/KCl column module and Agilent 490 Micro GC separates 14 C1 to C4 hydrocarbons in 200 seconds.
- Publication Part Number: A0906
- Created: 31 Oct 2011
- 675 KB
Publication Part Number | A00906 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 14 C1 to C6 hydrocarbon impurities in 1,3-butadiene in 15 minutes.
- Publication Part Number: A01122
- Created: 31 Oct 2011
- 424 KB
Publication Part Number | A01122 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column provides fast resolution of 14 C1 to C4 hydrocarbons in less than three minutes.
- Publication Part Number: A01096
- Created: 31 Oct 2011
- 585 KB
Publication Part Number | A01096 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|