Refine Results
- Content Type
-
Content Type
- Analyzed With
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 13 components in high-purity ethylene in 16 minutes.
- Publication Part Number: A0671
- Created: 31 Oct 2011
- 790 KB
Publication Part Number | A00671 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD 0.53 mm column is highly deactivated, with an excellent response when analyzing trace polar hydrocarbons, including acetylenes and dienes, in
- Publication Part Number: A02037
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02037 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 15 C1 to C4 light hydrocarbons in eight minutes.
- Publication Part Number: A0253
- Created: 31 Oct 2011
- 463 KB
Publication Part Number | A00253 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC analysis of C1 to C4 hydrocarbons is achieved in 15 minutes using the Agilent J&W Select Al2O3 MAPD.
- Publication Part Number: A02042
- Created: 31 Oct 2011
- 990 KB
Publication Part Number | A02042 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 C1 to C4 light hydrocarbons in ten minutes.
- Publication Part Number: A0227
- Created: 31 Oct 2011
- 523 KB
Publication Part Number | A00227 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates 14 impurities in propylene in 25 minutes.
- Publication Part Number: A01353
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A01353 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast analysis of light hydrocarbons in under 100 s is achieved using a short, 0.53 mm id Agilent J&W CP-Al2O3/KCl PLOT column with micro-volume direct injection.
- Publication Part Number: A01921
- Created: 01 Oct 2011
- 729 KB
Publication Part Number | A01921 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|