Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Instrument
Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
7890B Packed Column Refinery Gas analysis using the G3507A Large Valve Oven
- Publication Part Number: 5991-3535EN
- Created: 25 Nov 2013
- 1 MB
Publication Part Number | 5991-3535EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Analysis of C1 to C10 Hydrocarbons including C1 to C6 Paraffin/Olefin Isomer Separation at Ambient temperature Using Dual FID and a Capillary Flow Technology Deans Switch
- Publication Part Number: 5991-3253EN
- Created: 27 Sep 2013
- 141 KB
Publication Part Number | 5991-3253EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Agilent J&W PLOT PT columns with permanent integral traps show no spikes, indicating effective particle retention, have no potential for leaks and the ends can be trimmed.
- Publication Part Number: 5991-2975EN
- Created: 26 Aug 2013
- 638 KB
Publication Part Number | 5991-2975EN | ||||||||
---|---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||||
Instrument |
|
||||||||
Analytical Technique | Technique |
|
|||||||
Injection |
|
||||||||
Detection |
|
||||||||
Sample | Chemical Group |
|
|||||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Thermal desorption system for on-line monitoring of a complex mix of volatile and very volatile hydrocarbons (ozone Precursors) in air.
- Publication Part Number: 5991-2823EN
- Created: 26 July 2013
- 1 MB
Publication Part Number | 5991-2823EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机An Agilent 7890 Series GC configured with an HPLI with post-column backflushing improves the analysis of trace hydrocarbon impurities in monomer grade 1,3-Butadiene.
- Publication Part Number: 5991-1672EN
- Created: 18 Dec 2012
- 1 MB
Publication Part Number | 5991-1672EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
An improved gas chromatographic method based on a 7890 Series GC for the analysis of trace hydrocarbon impurities in monomer grade 1, 3-Butadiene has been developed.
- Publication Part Number: 5991-1499EN
- Created: 29 Nov 2012
- 2 MB
Publication Part Number | 5991-1499EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Describing the detailed separation of C1-C5 Light Hydrocarbons on CP-Al2O3/Na2SO4.
- Publication Part Number: SI-02644
- Created: 27 Sep 2012
- 150 KB
Publication Part Number | SI-02644 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-AL2O3/Na2SO4 column separates butenes in a butane stream in 22 minutes.
- Publication Part Number: A01513
- Created: 31 Oct 2011
- 646 KB
Publication Part Number | A01513 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Acetylene, methylacetylene, and propadiene impurities, among others, are present in propylene.Specifications are set on these polar hydrocarbons.必威体育登录手机The Agilent J&W Select Al2O3
- Publication Part Number: A02036
- Created: 31 Oct 2011
- 634 KB
Publication Part Number | A02036 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates nine chlorinated volatiles and hydrocarbons in 14 minutes.
- Publication Part Number: A01289
- Created: 31 Oct 2011
- 806 KB
Publication Part Number | A01289 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 16 C1 to C7 hydrocarbons in natural gas in 25 minutes.
- Publication Part Number: A0117
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A00117 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates five C1 to C2 hydrocarbon impurities in ethylene in eight minutes.
- Publication Part Number: A00579
- Created: 31 Oct 2011
- 508 KB
Publication Part Number | A00579 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C3 to C4 impurities in 1,2-butadiene in 20 minutes.
- Publication Part Number: A00594
- Created: 31 Oct 2011
- 774 KB
Publication Part Number | A00594 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates 15 C1 to C4 hydrocarbons in 24 minutes.
- Publication Part Number: A01294
- Created: 31 Oct 2011
- 968 KB
Publication Part Number | A01294 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD 0.53 mm column is highly deactivated, with an excellent response when analyzing trace polar hydrocarbons, including acetylenes and dienes, in
- Publication Part Number: A02037
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02037 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|