Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve column identifies the oxygen and argon content in a sample of high purity nitrogen in less than two minutes.
- Publication Part Number: A0767
- Created: 31 Oct 2011
- 359 KB
Publication Part Number | A00767 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates eight permanent gases in coke oven gas (detarred) in less than ten minutes.
- Publication Part Number: A0763
- Created: 31 Oct 2011
- 506 KB
Publication Part Number | A00763 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates oxygen, nitrogen, carbon monoxide and other gases in air in four minutes.
- Publication Part Number: A0495
- Created: 31 Oct 2011
- 486 KB
Publication Part Number | A00495 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates five permanent gases in less than three minutes.
- Publication Part Number: A01246
- Created: 31 Oct 2011
- 434 KB
Publication Part Number | A01246 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with Agilent J&W DB-FFAP and CP-Molsieve columns analyzes oxygen and water vapor in food packaging in less than four minutes.
- Publication Part Number: A01396
- Created: 31 Oct 2011
- 550 KB
Publication Part Number | A01396 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a thin-film Agilent J&W CP-Molsieve column separates four permanent gases in five minutes.
- Publication Part Number: A01248
- Created: 31 Oct 2011
- 477 KB
Publication Part Number | A01248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Molsieve 5Ã… column separates six permanent gases in 20 minutes.
- Publication Part Number: A0764
- Created: 31 Oct 2011
- 529 KB
Publication Part Number | A00764 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates six permanent gases in six minutes.
- Publication Part Number: A01245
- Created: 31 Oct 2011
- 394 KB
Publication Part Number | A01245 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates six permanent gases in eight minutes.
- Publication Part Number: A01247
- Created: 31 Oct 2011
- 467 KB
Publication Part Number | A01247 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates permanent gases in propylene in less than five minutes.
- Publication Part Number: A01272
- Created: 31 Oct 2011
- 880 KB
Publication Part Number | A01272 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates four permanent gases in five minutes.
- Publication Part Number: A01249
- Created: 31 Oct 2011
- 395 KB
Publication Part Number | A01249 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Molsieve separates oxygen, methane and carbon monoxide automatically in an effluent gas stream.
- Publication Part Number: A01846
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01846 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
406A.jpg
- Publication Part Number: 19095P-MS0
- Created: 08 May 2018
- 32 KB
- JPG
Publication Part Number | 406A | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
458C.jpg
- Publication Part Number: 19095P-MSO
- Created: 08 May 2018
- 30 KB
- JPG
Publication Part Number | 458C | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
- Publication Part Number: 19095P-MS6
- Created: 07 Sep 2004
- 23 KB
Publication Part Number | 19095p-ms6a | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|