Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Detection Technique
-
- Injection Technique
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机The environment of the reactor in a nuclear power plant cnn be checked for the presence of gases with portable Agilent 490 Micro GC with Agilent J&W CP-Molsieve 5Å.
- Publication Part Number: A01621
- Created: 12 Aug 2022
- 241 KB
Publication Part Number | A01621 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Molsieve 5Å column separates eight permanent gases at the ppm level in nine minutes.
- Publication Part Number: A0417
- Created: 10 Mar 2015
- 62 KB
Publication Part Number | A00417 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机This application note describes the use of an Agilent Micro GC for gas composition analysis during fuel cell research and development and beta testing.
- Publication Part Number: 5991-3364EN
- Created: 01 Dec 2014
- 332 KB
Publication Part Number | 5991-3364EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
A gas chromatography method has been developed for the analysis of natural gas and natural gas liquids by capillary column
- Publication Part Number: 5991-2063eN
- Created: 20 Mar 2013
- 183 KB
Publication Part Number | 5991-2063EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01242
- Created: 31 Oct 2011
- 382 KB
Publication Part Number | A01242 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01243
- Created: 31 Oct 2011
- 355 KB
Publication Part Number | A01243 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates six permanent gases in six minutes.
- Publication Part Number: A01245
- Created: 31 Oct 2011
- 394 KB
Publication Part Number | A01245 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates five permanent gases in less than three minutes.
- Publication Part Number: A01246
- Created: 31 Oct 2011
- 434 KB
Publication Part Number | A01246 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Agilent 490 Micro GC with an Agilent J&W CP-Molsieve 5Å analyzes air near a garbage dump for neon, hydrogen, oxygen, nitrogen, methane and carbon monoxide in 240 s.
- Publication Part Number: A01619
- Created: 31 Oct 2011
- 417 KB
Publication Part Number | A01619 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates six permanent gases in eight minutes.
- Publication Part Number: A01247
- Created: 31 Oct 2011
- 467 KB
Publication Part Number | A01247 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column and Agilent 490 Micro GC separates carbon monoxide, oxygen, and nitrogen in 55 seconds.
- Publication Part Number: A02063
- Created: 31 Oct 2011
- 585 KB
Publication Part Number | A02063 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column uses headspace analysis to identify cyanides in blood in less than four minutes.
- Publication Part Number: A01529
- Created: 31 Oct 2011
- 566 KB
Publication Part Number | A01529 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six gases in seven minutes.
- Publication Part Number: A0293
- Created: 31 Oct 2011
- 517 KB
Publication Part Number | A00293 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates four gases in five minutes.
- Publication Part Number: A0683
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00683 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin-film Agilent J&W CP-Molsieve column separates four permanent gases in five minutes.
- Publication Part Number: A01248
- Created: 31 Oct 2011
- 477 KB
Publication Part Number | A01248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with Agilent J&W DB-FFAP and CP-Molsieve columns analyzes oxygen and water vapor in food packaging in less than four minutes.
- Publication Part Number: A01396
- Created: 31 Oct 2011
- 550 KB
Publication Part Number | A01396 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates five gases in five minutes.
- Publication Part Number: A0307
- Created: 31 Oct 2011
- 368 KB
Publication Part Number | A00307 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates carbon dioxide in air in 20 seconds.
- Publication Part Number: A0288
- Created: 31 Oct 2011
- 272 KB
Publication Part Number | A00288 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates ten permanent gases and hydrocarbons in 15 minutes.
- Publication Part Number: A0680
- Created: 31 Oct 2011
- 504 KB
Publication Part Number | A00680 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column and Agilent 490 Micro GC separates oxygen and nitrogen in 40 seconds.
- Publication Part Number: A02061
- Created: 31 Oct 2011
- 678 KB
Publication Part Number | A02061 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|