Refine Results
- 必威体育赛事投注
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Instrument
-
必威体育登录手机Agilent 7696 Sample Prep WorkBench (1)
必威体育登录手机Agilent 7683B Automatic Liquid sampler (1)
Instrument
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
Publication Part Number | 5991-2153EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
DB-UI 8270D 0.18 mm id (with Ultra Inert liners) and 0.25 mm id columns provided excellent peak shapes and performance for semi-volatile water pollutants.
- Publication Part Number: 5991-0250EN
- Created: 24 Aug 2012
- 770 KB
Publication Part Number | 5991-0250EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Using the Agilent 7696A Sample Prep WorkBench to prepare calibration standards
- Publication Part Number: 5991-0973EN
- Created: 17 Aug 2012
- 684 KB
Publication Part Number | 5991-0973EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Japanese (Japan) | Complete (PDF) |
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates nine nitrosamines according to EPA8270 in less than 20 minutes.
- Publication Part Number: A02091
- Created: 31 Oct 2011
- 402 KB
Publication Part Number | A02091 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 13base neutrals according to EPA8270 in 20 minutes.
- Publication Part Number: A2090
- Created: 31 Oct 2011
- 503 KB
Publication Part Number | A02090 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|