Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Injection Technique
-
- Instrument
-
必威体育登录手机Agilent 7683 Automatic Liquid sampler (2)
必威体育登录手机Agilent 7000 Triple Quadrupole GC/MS (2)
Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
An analytical method that is well established for the 7000 Series Triple Quadrupole GC/MS has been employed to demonstrate performance of the 7000C Triple Quadrupole GC/MS.
- Publication Part Number: 5991-4131EN
- Created: 21 Mar 2014
- 180 KB
Publication Part Number | 5991-4131EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Fifteen days' exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
Publication Part Number | 5991-4110EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Application note for the multi-residue analysis of PAHs, PCBs and OCPs using an Agilent FactorFour VF-35ms Column
- Publication Part Number: SI-2396
- Created: 30 Jan 2014
- 274 KB
Publication Part Number | SI-02396 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Application note for the multi-residue analysis for PAHs, PCBs and OCPs on FactorFour VF-200ms
- Publication Part Number: SI-02467
- Created: 30 Jan 2014
- 348 KB
Publication Part Number | SI-02467 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Multi-residue analysis of PAHs, PCBs and OCPs was performed using GC/MS with Agilent J&W FactorFour VF-Xms column, demonstrating separation
- Publication Part Number: SI-02443
- Created: 09 Aug 2013
- 302 KB
Publication Part Number | SI-02443 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
A GC/MS/MS method for the analysis of pesticide residues in fruits and vegetables was developed, optimized, and successfully implemented
- Publication Part Number: 5991-1054EN
- Created: 11 Oct 2012
- 641 KB
Publication Part Number | 5991-1054EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Agilent Ultra Inert liners with wool give accurate and precise pesticide trace levels from 5 µL extracts in acetonitrile.
- Publication Part Number: 5991-1196EN
- Created: 04 Oct 2012
- 1 MB
Publication Part Number | 5991-1196EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Multi-residue analysis of PAHs, PCBs and OCPs in environmental samples using a GC-MS with a FactorFour VF-5ms column and quadrupole MS.
- Publication Part Number: SI-2364
- Created: 26 Sep 2012
- 167 KB
Publication Part Number | SI-02364 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Application note for the determination of pesticides in lemon oil via modified QuEChERS method
- Publication Part Number: 5990-6432EN
- Created: 06 Jan 2012
- 1 MB
Publication Part Number | 5990-6432EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS EN Kits by GC/MS
- Publication Part Number: 5990-4073EN
- Created: 06 Jan 2012
- 777 KB
Publication Part Number | 5990-4073EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (United States) | Complete (PDF) |
必威体育登录手机Application note for the analysis of Pesticide Residues in Apple by GC/MS using Agilent Bond Elut QuEChERS Kits for Preinjection Cleanup
- Publication Part Number: 5990-4468EN
- Created: 06 Jan 2012
- 217 KB
Publication Part Number | 5990-4468EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Describing the use of the AOAC buffered extraction method followed by the use of the Universal Dispersive SPE method for preparing lettuce and apple samples for GC/MS.
- Publication Part Number: 5990-6558EN
- Created: 06 Jan 2012
- 961 KB
Publication Part Number | 5990-6558EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS AOAC Kits by GC/MS
- Publication Part Number: 5990-4068EN
- Created: 06 Jan 2012
- 113 KB
Publication Part Number | 5990-4068EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (United States) | Complete (PDF) |
必威体育登录手机Application note for the analysis of Pesticide Residues in Spinach Using Agilent Bond Elut QuEChERS AOAC Kits by GC/MS
- Publication Part Number: 5990-4305EN
- Created: 06 Jan 2012
- 1,000 KB
Publication Part Number | 5990-4305EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (United States) | Complete (PDF) |
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 22 pesticides in 18 minutes.
- Publication Part Number: A01251
- Created: 31 Oct 2011
- 762 KB
Publication Part Number | A01251 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast GC separation of 15 pesticides, using a short 0.15 mm capillary, is achieved in 13 minutes with an Agilent J&W CP-Sil 5 CB column.
- Publication Part Number: A01650
- Created: 31 Oct 2011
- 708 KB
Publication Part Number | A01650 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 16 organochlorine pesticides according to EPA625 in 27 minutes.
- Publication Part Number: A02092
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A02092 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||