Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates four anesthetic gases in 18 minutes.
- Publication Part Number: A01627
- Created: 31 Oct 2011
- 403 KB
Publication Part Number | A01627 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column separates 14 reaction products of n-butane formed by CH3 radicals in 20 minutes.
- Publication Part Number: A0755
- Created: 31 Oct 2011
- 549 KB
Publication Part Number | A00755 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Trace level gases via GC/MS and a unique valve switching concept
- Publication Part Number: A01339
- Created: 31 Oct 2011
- 925 KB
Publication Part Number | A01339 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 C1 to C5 hydrocarbons and hydrogen sulfide in fuel gas in 16 minutes.
- Publication Part Number: A00574
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00574 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column analyzes eight decomposition gases from the explosive, 1,3,3-trinitroazetidine in 25 minutes.
- Publication Part Number: A01440
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A01440 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 13 sulfur compounds in a wine in 33 minutes.
- Publication Part Number: A0444
- Created: 31 Oct 2011
- 602 KB
Publication Part Number | A00444 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|