Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机A 29-component subset mix of basic, neutral, and acidic compounds was used to evaluate the Agilent J&W DB-UI 8270D Ultra Inert GC column, compared to a non-Agilent column
- Publication Part Number: 5991-1505EN
- Created: 15 Nov 2012
- 875 KB
Publication Part Number | 5991-1505EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
DB-UI 8270D 0.18 mm id (with Ultra Inert liners) and 0.25 mm id columns provided excellent peak shapes and performance for semi-volatile water pollutants.
- Publication Part Number: 5991-0250EN
- Created: 24 Aug 2012
- 770 KB
Publication Part Number | 5991-0250EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机GC/MS using an Agilent J&W CP-Sil 24 CB Low Bleed/MS column delivers highly selective trace analysis of 23 pesticide residues in surface water in 23 minutes.
- Publication Part Number: A01503
- Created: 31 Oct 2011
- 809 KB
Publication Part Number | A01503 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 14 organophosphorus pesticides in 27 minutes.
- Publication Part Number: A01108
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A01108 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The Agilent J&W VF-5ms GC column separates 51 pesticide residues in vegetable samples in 38 minutes.
- Publication Part Number: A02441
- Created: 11 May 2010
- 671 KB
Publication Part Number | A02441 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|