Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Instrument
-
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机An analytical method has been developed on the Agilent 7000 series GC/MS for the analysis of polyaromatic hydrocarbons and polybrominated diphenyl ethers in wastewater.
- Publication Part Number: 5991-0017EN
- Created: 14 Aug 2012
- 2 MB
Publication Part Number | 5991-0017EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Detailing polycyclic aromatic hydrocarbon (PAH) analysis in fish by GC/MS using Agilent Bond Elut QuEChERS dSPE sample prep and a high efficiency DB-5ms Ultra Inert GC column.
- Publication Part Number: 5990-6668EN
- Created: 06 Jan 2012
- 695 KB
Publication Part Number | 5990-6668EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
Russian (Russia) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates 111 C4 to C11 hydrocarbons in 49 minutes.
- Publication Part Number: A0903
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00903 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC with large volume injection on an Agilent J&W CP-Sil 24 CB column separates 88 surface water pollutants in 60 minutes with minimal sample preparation.
- Publication Part Number: A01500
- Created: 31 Oct 2011
- 642 KB
Publication Part Number | A01500 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with ion trap and an Agilent J&W VF-Xms column separates 16 polycyclic aromatic hydrocarbons in 18 minutes.
- Publication Part Number: A01967
- Created: 31 Oct 2011
- 587 KB
Publication Part Number | A01967 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast GC/MS with an Agilent J&W CP-Select 624 CB column separates 60 solvents in 16 minutes according to EPA 524.2.
- Publication Part Number: A01255
- Created: 31 Oct 2011
- 764 KB
Publication Part Number | A01255 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Select 624 CB column separates 52 C1 to C6 halogenated hydrocarbons and aromatic hydrocarbons in 50 minutes.
- Publication Part Number: A01233
- Created: 31 Oct 2011
- 824 KB
Publication Part Number | A01233 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Select 624 CB column separates 53 volatile organic compounds according to EPA 524 in 30 minutes.
- Publication Part Number: A01450
- Created: 31 Oct 2011
- 954 KB
Publication Part Number | A01450 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 27semivolatiles in indoor air in 40 minutes.
- Publication Part Number: A01901
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01901 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for the fast analysis of a Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar on Agilent J&W Select PAH GC Column
- Publication Part Number: SI-02279
- Created: 12 Apr 2011
- 1 MB
Publication Part Number | SI-02279 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Exploring techniques for determining chemical contaminants in marine shellfish using the Agilent 7000 Triple Quadrupole GC/MS System.
- Publication Part Number: 5990-7714EN
- Created: 06 Apr 2011
- 857 KB
Publication Part Number | 5990-7714EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Detailing the technique of PAH analysis using an Agilent J&W DB-5ms Ultra Inert Capillary GC Column.
- Publication Part Number: 5990-5652EN
- Created: 11 Feb 2011
- 131 KB
Publication Part Number | 5990-5652EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Application note for the analysis of Low-level Polycyclic Aromatic Hydrocarbons (PAHs) in Rubber and Plastic Articles
- Publication Part Number: 5990-6155EN
- Created: 12 Aug 2010
- 318 KB
Publication Part Number | 5990-6155EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Fast separation of 16 polyaromatic hydrocarbons in 17 minutes via GC/MS using an Agilent J&W VF-35ms column.
- Publication Part Number: A02410
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02410 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Determination of 18 polyaromatic hydrocarbons using Agilent J&W VF-35ms and GC/MS
- Publication Part Number: A02342
- Created: 11 May 2010
- 805 KB
Publication Part Number | A02342 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
444A.jpg
- Publication Part Number: 19091S-433\ TN= GC\
- Created: 08 May 2018
- 61 KB
- JPG
Publication Part Number | 444A | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
436B_024062.jpg
- Publication Part Number: 19191S-433\ TN= GC\ semivolatiles
- Created: 08 May 2018
- 50 KB
- JPG
Publication Part Number | 436B | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
442A.jpg
- Publication Part Number: 19091R-303
- Created: 08 May 2018
- 64 KB
- JPG
Publication Part Number | 442A | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Semivolatiles, EPA Method 624
- Publication Part Number: 19091S-433
- Created: 20 Mar 2017
- 91 KB
- JPG
Publication Part Number | 446C | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
- Publication Part Number: 19091S-133\ TN= GC\ EPA 8270
- Created: 27 Feb 2006
- 42 KB
Publication Part Number | C1080 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|