必威体育登录手机Gas chromatography and an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separate six alcohols and glycols in a water sample in seven minutes.
- Publication Part Number: A01330
- Created: 30 Nov 2015
- 860 KB
Publication Part Number | A01330 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates alcohols in blood/plasma in three minutes.
- Publication Part Number: A01323
- Created: 25 Aug 2015
- 392 KB
Publication Part Number | A01323 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Application note for glycol analysis by HPLC
- Publication Part Number: SI-02028
- Created: 11 Feb 2014
- 98 KB
Publication Part Number | SI-02028 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Application note for Volatile Organic Compounds in Serum or Plasma
- Publication Part Number: SI-2162
- Created: 29 Jan 2014
- 104 KB
Publication Part Number | SI-02162 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机An Agilent J&W DB-624UI column was compared with non-Agilent 624 phases, delivering better performance for C3 through C8 volatiles.
- Publication Part Number: 5991-1441EN
- Created: 08 Nov 2012
- 622 KB
Publication Part Number | 5991-1441EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Fast gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column at 100 kPa separates seven glycols in 60 seconds.
- Publication Part Number: A0691
- Created: 31 Oct 2011
- 750 KB
Publication Part Number | A00691 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates three solvents in ten minutes.
- Publication Part Number: A0278
- Created: 31 Oct 2011
- 422 KB
Publication Part Number | A00278 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机An Agilent J&W CP-Wax 52 CB column separates 22 solvents by gas chromatography in 40 minutes.
- Publication Part Number: A01952
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A01952 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates four glycols (ppm level) in water in 13 minutes.
- Publication Part Number: A0712
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00712 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC separation of ten glycols using an Agilent J&W CP-Wax 52 CB column with FID is achieved in under 40 minutes.
- Publication Part Number: A01954
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01954 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates impurities in propylene glycol in 30 minutes, according to DAB 1995/USP 23.
- Publication Part Number: A01385
- Created: 31 Oct 2011
- 562 KB
Publication Part Number | A01385 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 13 glycols and diols in less than 20 minutes.
- Publication Part Number: A01417
- Created: 31 Oct 2011
- 524 KB
Publication Part Number | A01417 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates mono-, di-, tri-, and tetraethylene glycols in 15 minutes.
- Publication Part Number: A0467
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A00467 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column uses on line analysis to identify diethylene glycol in monoethylene glycol in three minutes.
- Publication Part Number: A0657
- Created: 31 Oct 2011
- 449 KB
Publication Part Number | A00657 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates seven glycols and glycerols in eight minutes.
- Publication Part Number: A0770
- Created: 31 Oct 2011
- 522 KB
Publication Part Number | A00770 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 glycols in ten minutes.
- Publication Part Number: A0154
- Created: 31 Oct 2011
- 629 KB
Publication Part Number | A00154 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column identifies ethylene glycol impurity in 1,2-propyleneglycol in 17 minutes.
- Publication Part Number: A0609
- Created: 31 Oct 2011
- 659 KB
Publication Part Number | A00609 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Impurities in monoethylene glycol are detected by GC/MS with an Agilent J&W CP-Volamine column in six minutes.
- Publication Part Number: A01917
- Created: 01 Oct 2011
- 680 KB
Publication Part Number | A01917 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
MMEA and MDEA are used to remove sulfur compounds from hydrocarbons.必威体育登录手机Agilent J&W CP-Volamine is ideal for these highly polar compounds.
- Publication Part Number: A01914
- Created: 01 Oct 2011
- 792 KB
Publication Part Number | A01914 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS separation of three glycols in water using an Agilent J&W CP-Volamine column is achieved in 18 minutes.
- Publication Part Number: A01854
- Created: 01 Oct 2011
- 771 KB
Publication Part Number | A01854 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|