必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 88 column separates 16 fatty acid methyl esters of conjugated linoleic acids in soya bean oil in 50 minutes.
- Publication Part Number: A01649
- Created: 31 Oct 2011
- 752 KB
Publication Part Number | A01649 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC separation of four drugs of abuse on an Agilent J&W VF-5ms column in less than four minutes.
- Publication Part Number: A2070
- Created: 31 Oct 2011
- 710 KB
Publication Part Number | A02070 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Sil 5/C18 for PCB column separates seven polychlorinated biphenyl contaminants in a sample of transformer oil in 46 minutes.
- Publication Part Number: A01104
- Created: 31 Oct 2011
- 475 KB
Publication Part Number | A01104 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates ten phthalate esters in a plastic toy in 30 minutes.
- Publication Part Number: A01462
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01462 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W VF-Xms column delivers symmetrical peaks with virtually no bleed in the analysis of cholestanyl derivatives.
- Publication Part Number: A01963
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01963 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates 11 urea herbicides, derivatized with methyl iodide, in 30 minutes.
- Publication Part Number: A01228
- Created: 31 Oct 2011
- 413 KB
Publication Part Number | A01228 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 24 CB column resolves 22 methylated chlorophenoxycarboxylic acids in 35 minutes.
- Publication Part Number: A1090
- Created: 31 Oct 2011
- 649 KB
Publication Part Number | A01090 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using splitless injection with an Agilent J&W PoraBOND Q column separates 17 polar solvents in a water sample in 18 minutes.
- Publication Part Number: A01428
- Created: 31 Oct 2011
- 715 KB
Publication Part Number | A01428 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with headspace analysis and Agilent J&W CP-Select 624 CB separates eight residual solvents in 20 minutes according to European Pharmacopoeia and USP methods.
- Publication Part Number: A01265
- Created: 31 Oct 2011
- 512 KB
Publication Part Number | A01265 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS of an adipic ester is achieved in 20 minutes with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01653
- Created: 31 Oct 2011
- 519 KB
Publication Part Number | A01653 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W CP-Sil 24 CB Low Bleed/MS column delivers highly selective trace analysis of 23 pesticide residues in surface water in 23 minutes.
- Publication Part Number: A01503
- Created: 31 Oct 2011
- 809 KB
Publication Part Number | A01503 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates ten phenoxy herbicides in 34 minutes.
- Publication Part Number: A01230
- Created: 31 Oct 2011
- 405 KB
Publication Part Number | A01230 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB column separates 15 organochlorine pesticides in 29 minutes.
- Publication Part Number: A01109
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A01109 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Before GC with Agilent J&W CP-Sil 88 for FAME, C20:3 and C20:4 isomers are isolated by HPLC and fractionation to separate fatty acids by their double-bond positions.
- Publication Part Number: A01530
- Created: 31 Oct 2011
- 516 KB
Publication Part Number | A01530 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column analyzes ethylene oxide spiked with light hydrocarbons, vinyl chloride, and acetaldehyde in 15 minutes.
- Publication Part Number: A0674
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00674 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS of eight polycyclic aromatic hydrocarbons is accomplished in less than 20 minutes using an Agilent J&W CP-Sil 8 CB Low Bleed/MS column.
- Publication Part Number: A01655
- Created: 31 Oct 2011
- 610 KB
Publication Part Number | A01655 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Two Agilent GC columns are used in the analysis of polychlorinated biphenyls!必威体育登录手机a PDMS phase equivalent to Agilent J&W VF-1ms, and an Agilent J&W VF-23ms.
- Publication Part Number: A02095
- Created: 31 Oct 2011
- 807 KB
Publication Part Number | A02095 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 16 alcohols and esters in a sample of Chateau Ventenac 1988 red wine in 45 minutes.
- Publication Part Number: A0469
- Created: 31 Oct 2011
- 783 KB
Publication Part Number | A00469 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 12 triazine herbicides in 16 minutes.
- Publication Part Number: A0910
- Created: 31 Oct 2011
- 661 KB
Publication Part Number | A00910 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates chemical warfare agents in 24 minutes.
- Publication Part Number: A01617
- Created: 31 Oct 2011
- 489 KB
Publication Part Number | A01617 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|