必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates chemical warfare agents in 24 minutes.
- Publication Part Number: A01617
- Created: 31 Oct 2011
- 489 KB
Publication Part Number | A01617 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 40 polychlorinated biphenyls in the liver of an oyster catcher in 56 minutes.
- Publication Part Number: A0337
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00337 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates seven pesticides in potato, radish, and cabbage lettuce in 40 minutes.
- Publication Part Number: A0703
- Created: 31 Oct 2011
- 926 KB
Publication Part Number | A00703 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC with Agilent J&W CP-Sil 8 CB and PFPD is a highly sensitive and selective system capable of detecting a number of elements, 13 of these with ultimate selectivity.
- Publication Part Number: A01608
- Created: 31 Oct 2011
- 4 MB
Publication Part Number | A01608 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机GC/MS of 15 pesticides is achieved in 20 minutes using an Agilent J&W CP-Sil 8 CB column.
- Publication Part Number: A01656
- Created: 31 Oct 2011
- 688 KB
Publication Part Number | A01656 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five anabolic steroids in urine in 20 minutes.
- Publication Part Number: A00058
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00058 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 12 low-boiling, sulfur-containing compounds in 17 minutes.
- Publication Part Number: A0419
- Created: 31 Oct 2011
- 762 KB
Publication Part Number | A00419 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC/MS of 16 phthalate esters is achieved in 33 minutes using an Agilent J&W CP-Sil 8 CB column.
- Publication Part Number: A01657
- Created: 31 Oct 2011
- 675 KB
Publication Part Number | A01657 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 23 pesticides and polychlorinated biphenyls in a standard mixture in 26 minutes.
- Publication Part Number: A0478
- Created: 31 Oct 2011
- 699 KB
Publication Part Number | A00478 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||