必威体育登录手机as chromatography using an Agilent J&W CP-Sil 5 CB column separates six solvents in sewage water in 15 minutes.
- Publication Part Number: A0705
- Created: 31 Oct 2011
- 601 KB
Publication Part Number | A00705 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Si 5 CB column separates 35 solvents and contaminants in a sample of industrial waste water in 18 minutes.
- Publication Part Number: A01451
- Created: 31 Oct 2011
- 833 KB
Publication Part Number | A01451 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 57 halogenated hydrocarbon purgeables according to EPA 524.2 in 54 minutes.
- Publication Part Number: A0616
- Created: 31 Oct 2011
- 895 KB
Publication Part Number | A00616 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Separation of 11 aromatic volatiles on an Agilent J&W VF-200ms column in nine minutes.
- Publication Part Number: A02088
- Created: 31 Oct 2011
- 753 KB
Publication Part Number | A02088 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 71 halogenated hydrocarbons in water according to EPA 524.5, in 60 minutes.
- Publication Part Number: A1017
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 47 solvents and other volatiles according to EPA 8240 in 42 minutes.
- Publication Part Number: A0804
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A00804 | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 31 C6 to C13 polycyclic aromatic hydrocarbons in 51 minutes.
- Publication Part Number: A0652
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00652 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Cyclodextrin modification of the Agilent J&W CP-Chirasil DEX CB separates xylene isomers with high resolution, with very good separation of para and meta xylene.
- Publication Part Number: A01897
- Created: 01 Oct 2011
- 730 KB
Publication Part Number | A01897 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of 11 aromatic volatile compounds by gas chromatography using an Agilent J&W VF-1301ms column takes less than 15 minutes.
- Publication Part Number: A02413
- Created: 11 May 2010
- 782 KB
Publication Part Number | A02413 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机本文采用一台Agilent 7890B 氣相色譜係統完成水中四類有機化合物的檢測。
- Publication Part Number: 5991-2787CHCN
- Created: 05 Aug 2013
- 454 KB
Publication Part Number | 5991-2787EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|