Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Injection Technique
-
- Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Compared to other vendor's columns, Agilent J&W DB-CLP1/DB-CLP2 provides better combinations of faster analysis times and fewer coelutions,
- Publication Part Number: 5991-0615EN
- Created: 02 Aug 2012
- 2 MB
Publication Part Number | 5991-0615EN | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 18C1 to C2 halogenated hydrocarbons in air in ten minutes.
- Publication Part Number: A0299
- Created: 31 Oct 2011
- 755 KB
Publication Part Number | A00299 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 13 halogenated hydrocarbons in land fill gas in 28 minutes.
- Publication Part Number: A0300
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A00300 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates eight C1 to C2 halogenated hydrocarbons in air in 20 minutes.
- Publication Part Number: A1012
- Created: 31 Oct 2011
- 476 KB
Publication Part Number | A01012 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates nine volatile halogen compounds in a water sample.
- Publication Part Number: A00062
- Created: 31 Oct 2011
- 691 KB
Publication Part Number | A00062 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates three C2 halogenated hydrocarbons in water in 40 minutes.
- Publication Part Number: A1018
- Created: 31 Oct 2011
- 567 KB
Publication Part Number | A01018 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 71 halogenated hydrocarbons in water according to EPA 524.5, in 60 minutes.
- Publication Part Number: A1017
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机A gas chromatograph with a built in cryogenic concentrator and Agilent J&W CP-Select 624 CB column separates ten volatile organic compounds in a sample of ambient air.
- Publication Part Number: A01862
- Created: 01 Oct 2011
- 2 MB
Publication Part Number | A01862 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|