Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Language
-
Language
Applied Filters
FID detection fatty acid methyl esters (FAME) on a CP-Sil 88 for FAME GC column.
- Publication Part Number: SI-02178
- Created: 10 Nov 2015
- 133 KB
Publication Part Number | SI-02178 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Application note for the GC analysis of 37 FAME Component Mixture using CP-Select for FAME Column
- Publication Part Number: SI-2164
- Created: 30 Jan 2014
- 169 KB
Publication Part Number | SI-02164 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机A 15 m x 0.32 mm Agilent J&W CP-Wax 52CB column delivers very fast analysis of regular FAME compounds from canola oil by GC.Typical cycle times are under 5 minutes.
- Publication Part Number: A01988
- Created: 31 Oct 2011
- 807 KB
Publication Part Number | A01988 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column determines trace levels of amines in 25 minutes.
- Publication Part Number: A01278
- Created: 31 Oct 2011
- 577 KB
Publication Part Number | A01278 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 88 for FAME column separates 19 fatty acid methyl esters in 20 minutes.
- Publication Part Number: A00091
- Created: 31 Oct 2011
- 629 KB
Publication Part Number | A00091 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-FFAP column separates 23 C6 to C24 fatty acid methyl esters in 33 minutes.
- Publication Part Number: A0717
- Created: 31 Oct 2011
- 625 KB
Publication Part Number | A00717 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-1301 column separates 11 components in the Grob test mixture in 47 minutes.
- Publication Part Number: A01223
- Created: 31 Oct 2011
- 440 KB
Publication Part Number | A01223 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Fast GC analysis of eight FAMEs in butter is achieved in less than five minutes, using the Agilent J&W VF-23ms GC column.
- Publication Part Number: A01972
- Created: 31 Oct 2011
- 903 KB
Publication Part Number | A01972 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 13 CB column separates 12 components in the Grob test mixture in 45 minutes.
- Publication Part Number: A01222
- Created: 31 Oct 2011
- 452 KB
Publication Part Number | A01222 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 88 CB column separates 12 C4 to C18 fatty acid methyl esters in 15 minutes.
- Publication Part Number: A00080
- Created: 31 Oct 2011
- 433 KB
Publication Part Number | A00080 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography of fatty acid methyl esters in butter separates 20 FAMEs in less than 17 minutes using an Agilent J&W CP-Select CB for FAME column.
- Publication Part Number: A01777
- Created: 01 Oct 2011
- 825 KB
Publication Part Number | A01777 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select CB for Fame column separates 19 fatty acid methyl esters in under 60 minutes.
- Publication Part Number: A01911
- Created: 01 Oct 2011
- 769 KB
Publication Part Number | A01911 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Application note for the analysis of fatty acids in Infant Formulas Using a J&W HP-88 Capillary GC Column
- Publication Part Number: 5990-8429EN
- Created: 17 June 2011
- 426 KB
Publication Part Number | 5990-8429EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|