必威体育登录手机The inertness of the Agilent PoraPLOT Q-HT guarantees a high response for polar compounds, also at low concentrations.
- Publication Part Number: A01300
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A01300 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Using Agilent PoraPLOT Q-HT columns water elutes very quickly from the hydrophobic porous polymers and can be analyzed directly without using titration techniques.
- Publication Part Number: A01301
- Created: 31 Oct 2011
- 574 KB
Publication Part Number | A01301 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 18 solvents in less than 11 minutes.
- Publication Part Number: A01563
- Created: 31 Oct 2011
- 584 KB
Publication Part Number | A01563 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates seven residual solvents in a drug in ten minutes.
- Publication Part Number: A01302
- Created: 31 Oct 2011
- 594 KB
Publication Part Number | A01302 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates nine solvents in 11 minutes.
- Publication Part Number: A0905
- Created: 31 Oct 2011
- 696 KB
Publication Part Number | A00905 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 26 pharmacopoeia-specified solvents in 30 minutes.
- Publication Part Number: A01304
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A01304 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 36 solvents in 41 minutes.
- Publication Part Number: A01318
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01318 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 32 solvents in 44 minutes, according to USP 467.
- Publication Part Number: A01546
- Created: 31 Oct 2011
- 892 KB
Publication Part Number | A01546 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 623 CB column separates 23 solvents in 20 minutes.
- Publication Part Number: A01280
- Created: 31 Oct 2011
- 855 KB
Publication Part Number | A01280 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 18 C1 to C11 volatile alcohols, ketones, and ethers in 20 minutes.
- Publication Part Number: A0157
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00157 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 16 solvents in 21minutes.
- Publication Part Number: A00502
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00502 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with headspace analysis and an Agilent J&W CP-Select 624 CB column separates 18 solvent standards in DMSO in 30 minutes.
- Publication Part Number: A01389
- Created: 31 Oct 2011
- 573 KB
Publication Part Number | A01389 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine volatile ketones and alcohols in water in 18 minutes.
- Publication Part Number: A0120
- Created: 31 Oct 2011
- 428 KB
Publication Part Number | A00120 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a 0.15 mm id Agilent J&W CP-Sil 5 CB column reduces run time in the separation of residual solvents from 25 minutes to less than seven minutes.
- Publication Part Number: A01501
- Created: 31 Oct 2011
- 660 KB
Publication Part Number | A01501 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates five solvents in air in 100 seconds.
- Publication Part Number: A00947
- Created: 31 Oct 2011
- 636 KB
Publication Part Number | A00947 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates ten solvents in five minutes.
- Publication Part Number: A0681
- Created: 31 Oct 2011
- 568 KB
Publication Part Number | A00681 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 25 constituents in a toluene sample in 17 minutes.
- Publication Part Number: A01281
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01281 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q-HT column separates 18 solvents in 50 minutes.
- Publication Part Number: A01256
- Created: 31 Oct 2011
- 638 KB
Publication Part Number | A01256 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight solvents in 25 minutes.
- Publication Part Number: A0608
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A00608 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 47 solvents and other volatiles according to EPA 8240 in 42 minutes.
- Publication Part Number: A0804
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A00804 | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|