必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column and Agilent 490 Micro GC separates ethylene chloride and water impurities in vinyl chloride in 90 seconds.
- Publication Part Number: A02213
- Created: 29 Apr 2015
- 115 KB
Publication Part Number | A02213 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four solvents in a gas mix in 220 seconds.
- Publication Part Number: A0888
- Created: 31 Oct 2013
- 408 KB
Publication Part Number | A00888 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Agilent J&W HP-PLOT Q PT and HP-PLOT U PT GC columns were evaluated for coal-to-chemical process gas analysis by GC/TCD and GC/MS detection.
- Publication Part Number: 5991-2205EN
- Created: 03 Apr 2013
- 262 KB
Publication Part Number | 5991-2205EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates carbonyl sulfide and ethylene in seven minutes.
- Publication Part Number: A01260
- Created: 31 Oct 2011
- 486 KB
Publication Part Number | A01260 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in less than 10 minutes using Agilent PLOT columns in tandem, with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02028
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02028 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates impurities in a pharmaceutical grade isopropanol in five minutes.
- Publication Part Number: A01419
- Created: 31 Oct 2011
- 443 KB
Publication Part Number | A01419 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates hydrochloric acid and water in less than seven minutes, withstanding repeated injections of HCl very well.
- Publication Part Number: A01601
- Created: 31 Oct 2011
- 325 KB
Publication Part Number | A01601 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Volamine column elutes volatile amines as symmetrical peaks, as well as low levels of alcohols, air and water.
- Publication Part Number: A01586
- Created: 31 Oct 2011
- 679 KB
Publication Part Number | A01586 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates C2 hydrocarbons to base line in two minutes.
- Publication Part Number: A01587
- Created: 31 Oct 2011
- 382 KB
Publication Part Number | A01587 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机On-site air is monitored with Agilent 490 Micro GC and Agilent J&W CP-Sil 8 CB.Target components are aromatics, which can be measured within 150 s down to ppm.
- Publication Part Number: A01622
- Created: 31 Oct 2011
- 500 KB
Publication Part Number | A01622 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-SilicaPLOT column separates seven sulfur compounds in 25 minutes.
- Publication Part Number: A01257
- Created: 31 Oct 2011
- 524 KB
Publication Part Number | A01257 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates water in nine solvents in less than seven minutes.
- Publication Part Number: A00582
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A00582 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column produces good peak shapes in the analysis of halogenated hydrocarbons.
- Publication Part Number: A01588
- Created: 31 Oct 2011
- 471 KB
Publication Part Number | A01588 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates three components in an air sample in two minutes.
- Publication Part Number: A0282
- Created: 31 Oct 2011
- 354 KB
Publication Part Number | A00282 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten propellants and solvents in aerosol containers in six minutes.
- Publication Part Number: A0333
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00333 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column and Agilent 490 Micro GC separates carbon dioxide and water impurities in ethylene oxide in 26 seconds.
- Publication Part Number: A02060
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02060 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates carbon dioxide and water in a breath sample in two minutes.
- Publication Part Number: A0279
- Created: 31 Oct 2011
- 296 KB
Publication Part Number | A00279 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column separates 14 reaction products of n-butane formed by CH3 radicals in 20 minutes.
- Publication Part Number: A0755
- Created: 31 Oct 2011
- 549 KB
Publication Part Number | A00755 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 C1 to C5 hydrocarbons and hydrogen sulfide in fuel gas in 16 minutes.
- Publication Part Number: A00574
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00574 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in less than 20 minutes using Agilent PLOT columns in tandem, with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02031
- Created: 31 Oct 2011
- 616 KB
Publication Part Number | A02031 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|