Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates ten solvents in five minutes.
- Publication Part Number: A0681
- Created: 31 Oct 2011
- 568 KB
Publication Part Number | A00681 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates volatile halogenated hydrocarbons in a hydrocarbon/water mixture in less than four minutes.
- Publication Part Number: A01324
- Created: 31 Oct 2011
- 538 KB
Publication Part Number | A01324 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates seven C3 to C8 ketones in 10 minutes.
- Publication Part Number: A0682
- Created: 31 Oct 2011
- 445 KB
Publication Part Number | A00682 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates six permanent gases in water in four minutes.
- Publication Part Number: A0684
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A00684 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates six C1 to C3 hydrocarbons and polar volatiles in five minutes.
- Publication Part Number: A0686
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00686 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with Agilent J&W PoraPLOT U and PoraPLOT Q columns separate seven C1 to C3 hydrocarbons and chloromethane in 12 minutes.
- Publication Part Number: A00575
- Created: 31 Oct 2011
- 595 KB
Publication Part Number | A00575 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates four gases in five minutes.
- Publication Part Number: A0683
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00683 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates four C1 to C4 hydrocarbons in two minutes at 30 oC and 1 minute at 60 oC.
- Publication Part Number: A0685
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00685 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column determines mg/L levels of water in pure propylene oxide in three minutes.
- Publication Part Number: A0758
- Created: 31 Oct 2011
- 356 KB
Publication Part Number | A00758 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column analyzes ethylene oxide spiked with light hydrocarbons, vinyl chloride, and acetaldehyde in 15 minutes.
- Publication Part Number: A0674
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00674 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with the Agilent J&W PoraPLOT Q separates nine impurities in vinylchloride in 23 minutes.
- Publication Part Number: A01902
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01902 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|